一种用于深度地质物理调查的两种不同地震源交替拍摄的新方法
ChenGuang Liu1, JinZhong Fu1, QingFeng Hua1
1Key Laboratory of Marine Geology and Metallogeny, The First Institute of Oceanography, Ministry of Natural Resources, Qingdao, 266061, China.
Scientific reports
|June 19, 2023
概括
一种新的地质物理调查方法使用双重地震源,同时获取海面和海底数据. 这种创新方法提高了海上深海地震调查的效率和数据丰富性.
科学领域:
- 地质物理学 地质物理学
- 海洋地质学 海洋地质学
- 地震勘探的地震勘探工作
背景情况:
- 传统的地震调查在实现深度透和全面数据采集方面存在局限性.
- 印度洋的九十东是地球物理研究的关键区域.
研究的目的:
- 引入和评估一种用于比例双重地震源激发的新方法.
- 从海面和海底同时获取地震数据.
主要方法:
- 使用了两个不同的地震源:G炮阵列 (450英寸3容量,20-100赫兹) 和博尔特炮阵列 (6000英寸3容量,10-40赫兹).
- 采用480通道的地震流器和21个海底地震计 (OBS) 来接收信号.
- 在G枪和Bolt枪阵列之间实现了3:1的触发信号分配比.
主要成果:
- 成功生成了三种类型的地震配置文件:常规 (2公里透),深 (6公里透) 和主动源OBS (30公里透).
- 从多个接收器和来源同时采集数据.
结论:
- 这种新方法显著提高了离岸深海地震调查的效率.
- 提供更丰富的数据集,具有不同的透深度,用于增强地质解释.
相关概念视频
Double Resonance Techniques: Overview
248
Double resonance techniques in Nuclear Magnetic Resonance (NMR) spectroscopy involve the simultaneous application of two different frequencies or radiofrequency pulses to manipulate and observe two distinct nuclear spins. One important application of double resonance is spin decoupling, which selectively suppresses coupling with one type of nucleus while observing the NMR signal from another nucleus, simplifying the spectrum and enhancing resolution.
Spin decoupling is usually achieved by...
Spin decoupling is usually achieved by...
248
Types of Global Positioning System Surveys
83
GPS surveying methods vary in application, accuracy, and data collection techniques, catering to diverse surveying and mapping needs. Static GPS, kinematic GPS, and real-time kinematic (RTK) surveying are widely used. Each technique offers distinct advantages.Static GPS involves placing one receiver at a known reference point and another at the target point. It collects exact positional data by observing multiple satellite ranges over an extended period, achieving centimeter-level accuracy for...
83
Tandem Mass Spectrometry
1.1K
Tandem mass spectrometry is a technique that uses multiple mass analyzers in series to obtain a higher selectivity and signal-to-noise ratio for the analyte. Instruments with multiple analyzers separated by an interaction cell enable secondary fragmentation and selected study of the fragment ions.
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
1.1K