电荷检测质谱中的动态能量测量消除了离子-离子相互作用的不利影响
Conner C Harper1, Veena S Avadhani1, Emeline Hanozin1
1Department of Chemistry, University of California, Berkeley, California 94720-1460, United States.
Analytical chemistry
|June 21, 2023
概括
研究了电荷检测质谱法 (CDMS) 中的离子-离子相互作用. 尽管存在潜在的影响,但这些相互作用对使用动态测量方法的质量准确性影响微不足道.
科学领域:
- 分析化学 分析化学
- 物理化学 物理化学
- 质谱测量质量谱测量
背景情况:
- 电荷检测质谱仪 (CDMS) 中的离子-离子相互作用没有得到充分的记录.
- 模拟表明,这些相互作用可以通过影响离子能量来降低测量性能.
研究的目的:
- 为了研究CDMS中与同时被困的离子之间的离子-离子相互作用.
- 量化这些相互作用对质量,电荷和能量测量的影响.
主要方法:
- 利用动态测量方法,在捕获寿命中追踪单个离子属性.
- 研究的离子质量从2到350MDa,电荷从100到1000.
- 雇佣了短时间的福里埃变换分析用于光谱数据.
主要成果:
- 在物理相互作用的离子之间观察到的能量转移具有高分辨率 (∼950).
- 发现相互作用离子的质量和电荷保持不变,而测量不确定性没有增加.
- 证明了通过参数选择可以减轻光谱泄漏工件.
结论:
- 在CDMS中同时捕获多个离子可以减少数据采集时间.
- 在使用动态测量方法时,CDMS中的离子-离子相互作用不会显著影响质量的准确性.
更多相关视频
12:11Simultaneous Affinity Enrichment of Two Post-Translational Modifications for Quantification and Site Localization
Published on: February 27, 2020
6.9K
08:22Measurement of Ultrafast Vibrational Coherences in Polyatomic Radical Cations with Strong-Field Adiabatic Ionization
Published on: August 6, 2018
6.9K
相关概念视频
Mass Analyzers: Common Types
659
The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
659
Electrospray Ionization (ESI) Mass Spectrometry
962
Higher molecular weight biomolecules are nonvolatile compounds that may decompose before ionizing or vaporizing during mass analysis with conventional electron impact ionization methods. Accordingly, electrospray ionization (ESI) is the favored method for vaporizing and ionizing biomolecules as it circumvents rapid fragmentation and enables the recording of mass signals for the entire biomolecule.
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
962
Mass Spectrometers
5.7K
This lesson details the instrumentation of a mass spectrometer—a physical instrument to perform mass spectrometry on analyte molecules and record the characteristic mass spectra. This is achieved via three chief functions:
5.7K
High-Performance Liquid Chromatography: Types of Detectors
629
The role of the detectors in High-Performance Liquid Chromatography (HPLC) is to analyze the solutes as they exit from the chromatographic column. The detector recognizes the solute's property and generates corresponding electrical signals, which are converted into a readable graph of the detector's response versus elution time called a chromatogram at the computer. There are several types of HPLC detectors, each with its own advantages and limitations, depending on the analyte...
629
Mass Spectrometry: Overview
5.5K
Mass spectrometry is an analytical technique used to determine the molecular mass and molecular formula of a compound. The basic principle of mass spectrometry is to generate ions from the analyte molecule and measure these ion abundances against their molecular mass. One common type of ionization, known as electrospray ionization or EI, bombards the analyte molecules in the gas phase with high-energy electron beams. The electron beams displace an electron from the molecule and leave...
5.5K
Mass Analyzers: Overview
743
The mass analyzer is a crucial component of the mass spectrometer. In the ionization chamber, the vaporized sample is bombarded with a high-energy electron beam to generate a radical cation and further fragment into neutral molecules, radicals, and cations. A series of negatively charged accelerator plates accelerate the cations into the mass analyzer. The mass analyzer separates ions according to their mass-to-charge (m/z) ratios and then directs them to the detector. The common types of mass...
743