石头制造的防风结构对一个干旱的内布卡沙丘前沿的影响
Abel Sanromualdo-Collado1, Leví García-Romero2, Manuel Viera-Pérez1
1Grupo de Geografía Física y Medio Ambiente, Instituto de Oceanografía y Cambio Global, IOCAG, Universidad de Las Palmas de Gran Canaria, ULPGC, Spain.
The Science of the total environment
|June 21, 2023
概括
海游客建造的石头防风棚通过改变空气流和沉积物动态来破坏干旱的沙丘生态系统. 它们的去除可以帮助恢复沙丘的生长和植被,但需要仔细规划以避免进一步的损害.
科学领域:
- 地质形态学 地质形态学
- 生态生态学 生态生态学
- 沿海科学 沿海科学
背景情况:
- 海使用者在干旱的海岸线上建造石头的风避难所 (goros),影响沙丘系统.
- 这些人造结构可以长期存在,影响自然的生物地形学过程.
- 戈罗斯对干旱的沙 - 沙丘动态的影响,特别是内布哈形成,尚未得到充分研究.
研究的目的:
- 为了研究石头防风棚对干旱沙-沙丘系统动态的影响.
- 分析戈罗斯对沉积物积累,空气流和植被的影响.
- 为仔细拆除这些结构提供建议.
主要方法:
- 对空中摄影的分析,以追踪石头避难所的演变.
- 收集关于内布哈地形,空气流和植被变化的现场数据.
- 试验性从代表性内布卡中移除石头,以监测效应.
主要成果:
- 石头堆叠大大改变了地形周围的空气流和沉积物运输.
- 戈洛斯限制了内布卡斯内沉积物的积累,阻碍了干旱的前的生长.
- 植被生长和沉积物保留受到石头庇护所的约束.
结论:
- 人工石结构对干旱沙丘生态系统的功能产生负面影响.
- 移除戈洛斯可以扭转负面影响,但需要仔细规划来保护植被.
- 对于具有高游客影响的沿海地区,需要可持续的管理策略.
相关概念视频
Masonry in Cold and Hot Weather Conditions
111
In cold weather, masonry construction requires specific precautions to ensure mortar does not freeze before curing, as this can significantly weaken its strength and watertightness. Mortar temperature should be maintained between 60°F and 80°F to support proper hydration and curing. Below 40°F, mortar water must be heated, but should not exceed 120°F as high temperatures can reduce mortar's compressive and bond strength.
Other key practices include keeping masonry units...
Other key practices include keeping masonry units...
111
Thermal Insulation in Masonry Walls
152
In hot, dry climates, the thermal mass of masonry walls can be beneficial, absorbing heat during the day and releasing it at night, thereby stabilizing indoor temperatures. However, in most other climates, additional insulation is necessary to enhance thermal resistance.
External insulation can be applied using an Exterior Insulation and Finish System (EIFS), which involves affixing panels of plastic foam to the wall and covering them with a polymeric stucco reinforced with glass fiber mesh....
External insulation can be applied using an Exterior Insulation and Finish System (EIFS), which involves affixing panels of plastic foam to the wall and covering them with a polymeric stucco reinforced with glass fiber mesh....
152
Stone Masonry
132
Stone masonry is a construction technique that uses individual stones to build structures and can be categorized into two main types: rubble and ashlar. Rubble masonry uses uneven, naturally shaped stones such as river rocks or fragments from quarries. This method often requires the mason to select and possibly shape each stone to fit the designated space, ensuring a proper build, even with irregular stone sizes and shapes. Ashlar masonry, on the other hand, employs uniformly cut stones that...
132
Frost Resistant Concrete
108
Concrete's susceptibility to frost damage during freeze-thaw cycles demands strategic measures to enhance its frost resistance. Employing techniques like air entrainment, adjusting the water-cement ratio, proper curing, and selecting appropriate aggregates are essential.
Introducing microscopic air bubbles into the concrete mix through air entrainment creates small voids that accommodate ice expansion, thereby reducing internal pressures and preventing cracking. The optimal amount of...
Introducing microscopic air bubbles into the concrete mix through air entrainment creates small voids that accommodate ice expansion, thereby reducing internal pressures and preventing cracking. The optimal amount of...
108
Mortar Joint Deterioration in Masonry
140
Mortar joint deterioration is a significant concern in masonry structures, with water accumulation in the joints leading to damage from freeze-thaw cycles. The repeated expansion of water during freezing and its melting during thawing develop and propagate cracks in the masonry joints. Eventually, this leads to the spalling of mortar from the joints, loosening masonry units and weakening the structure. The deteriorated mortar joints are also vulnerable to moisture intrusion into the walls.
The...
The...
140
Design Example: Calculating Safe Diameter for Wind-Exposed Disc
156
Assessing safety in wind-exposed installations is crucial to preventing potential failures. This example explores the calculation and design adjustments needed to mount a circular disc on a building facade, where wind forces are a primary concern. A 4-meter diameter disc was initially designed as an aesthetic feature facing winds at a velocity of 25 meters per second, with an air density of 1.25 kilograms per cubic meter. Given these conditions, the drag force on the disc was determined using...
156


