强大的级联控制器用于三相电源的功率因子和感应电机速度
Onofre A Morfin1, Riemann Ruiz-Cruz2, Fredy A Valenzuela3
1Depto. de Electrica y Computacion, Instituto de Ingenieria y Tecnologia, Universidad Autonoma de Ciudad Juarez, Mexico.
ISA transactions
|June 23, 2023
概括
本研究介绍了一种用于功率转换器的新型控制系统,允许感应电机向电网输送反应功率,同时改善功率因子和电机转速调节.
科学领域:
- 电气工程 电气工程
- 电力电子 电力电子 电力电子
- 控制系统 控制系统
背景情况:
- 感应电机消耗主动和反应功率,导致电网功率因子降低.
- 驱动感应电机的功率转换器产生电流波,进一步降低功率质量.
研究的目的:
- 介绍一个新的控制系统,用于背对背电源转换器,以提高电网功率因子.
- 为了使功率转换器能够在控制感应电机转速的同时向电网输送调节的反应功率.
主要方法:
- 使用线性化,状态反和超扭曲策略开发了一个强大的控制系统.
- 该系统包含一个背对背转换器,一个LCL过器和一个在变量负载下的感应电机.
- 控制器旨在取消非线性和外部干扰,以实现稳健的操作.
主要成果:
- 拟议的系统成功地向电网输送反应电力,从而提高功率因子.
- 实现了同步调节感应电机转速和反应功率的传输.
- 实验测试表明,在突然的负载变化下,控制器的稳定性得到了证明.
结论:
- 开发的强大的控制系统为改善感应电机驱动器功率因子提供了完整的解决方案.
- 该系统有效地管理反应功率,并减轻电流波.
- 控制器对干扰和负载变化表现出显著的稳定性.
更多相关视频
06:45Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator
Published on: October 28, 2022
1.7K
09:04A Modeling and Simulation Method for Preliminary Design of an Electro-Variable Displacement Pump
Published on: June 1, 2022
3.1K
相关概念视频
Three-Phase Circuits
438
AC power distribution systems have three categories: single-phase, two-phase, and three-phase systems. The single-phase circuit, common in residential settings, typically employs a two-wire system connecting a single AC source to various loads. These circuits support standard household appliances operating at 120 volts (V) and 240 V, such as lamps, televisions, and microwaves. The first generators, Niagara Falls hydro plant installed in 1895, were two-phase and designed by Nikola Tesla. The...
438
Power in a Three-Phase Circuit
368
Three-phase systems have two configurations: the wye and delta. A star configuration can be three or four wires; in a delta configuration, the components are connected in a closed loop. Instantaneous power refers to the power value at a precise moment, and in a balanced three-phase system, it is constant. This is because the sum of the instantaneous powers in the three phases remains steady over time, despite individual fluctuations, due to the symmetry and phase relationship. The total...
368
Generation of Three-Phase Voltage
420
A three-phase AC generator has a rotor with a rotating magnet placed within the stator mounted with the stationary three-phase winding to generate three-phase voltages via mutual induction. These windings are evenly distributed around the inner circumference of the stator and are arranged 120 electrical degrees apart. Three-phase stator windings consist of three separate coils or groups of coils, known as phases, each connected in Y (star) configuration or Delta configuration.
As the rotor...
As the rotor...
420
Time-Domain Interpretation of PD Control
146
Proportional-Derivative (PD) control is a widely used control method in various engineering systems to enhance stability and performance. In a system with only proportional control, common issues include high maximum overshoot and oscillation, observed in both the error signal and its rate of change. This behavior can be divided into three distinct phases: initial overshoot, subsequent undershoot, and gradual stabilization.
Consider the example of control of motor torque. Initially, a positive...
Consider the example of control of motor torque. Initially, a positive...
146
PID Controller
156
Proportional-Integral-Derivative (PID) controllers are widely used in various control systems to enhance stability and performance. In a thermostat, it adjusts heating or cooling based on the temperature difference between the actual and desired levels. They are often used in automotive speed systems, effectively managing sudden speed changes while maintaining a constant speed under varying conditions. On the other hand, PI controllers, commonly employed in voltage regulation, enhance stability...
156
Phase-lead and Phase-lag Controllers
201
Understanding the working function of different types of controllers can be illustrated with practical analogies, such as adjusting a stereo's volume equalizer. Cranking up the bass involves a phase-lead controller, which functions as a high-pass filter, while increasing the treble uses a phase-lag controller, which acts as a low-pass filter. PD controllers, similar to high-pass filters, enhance the system's response to high-frequency components. PI controllers, akin to low-pass...
201