相关实验视频
Updated: Jul 25, 2025

08:43
Potentiodynamic Corrosion Testing
Published on: September 4, 2016
17.7K
对HVDC传输接地电极对管道阴极保护系统的干扰的研究
1Key Laboratory of Shaanxi Province for Gas-Oil Logging Technology, Xi'an Shiyou University, Xi'an, Shaanxi 710065, China.
ACS omega
|June 26, 2023
概括
高压直流传输接地电极可以干扰附近的长途管道.
科学领域:
- 电气工程 电气工程
- 腐蚀科学 腐蚀科学
- 地质物理学 地质物理学
背景情况:
- 长途石油和天然气运输主要依赖于管道.
- 高压直流传输系统使用接地电极,可能会干扰相邻的基础设施.
- 阴极保护是防止管道腐蚀的关键方法.
研究的目的:
- 调查高压直流传输接地电极对附近长途管道的正极保护系统的影响.
- 在各种操作和环境条件下建模和分析干扰效应.
主要方法:
- 开发了一个直流传输接地电极和管道的正极保护系统的COMSOL多物理干扰模型.
- 使用实验数据验证了模型.
- 在不同的接地电极电流,距离,土壤导电性和涂层阻力下模拟和计算电流密度和电位分布.
主要成果:
- 获得了管道的详细电流密度和正极保护电位分布规律.
- 视觉化了由于DC接地电极在单极模式下运行而发生在相邻管道中的腐蚀.
- 确定了影响干扰效应的关键参数.
结论:
- 直流传输接地电极可以对管道正极保护系统产生负面影响.
- 了解这些干扰效应对于确保管道完整性和防止腐蚀至关重要.
- 这项研究为评估和减轻这种干扰提供了有价值的工具.
相关概念视频
Line Protection with Impedance Relays
106
Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
Under normal conditions, low load currents keep the measured...
106
Insulation Coordination
174
Insulation coordination is the process of matching electric equipment's insulation strength with protective device characteristics to protect the equipment against expected overvoltages. This selection is based on engineering judgment and cost. Equipment can generally withstand short-duration high transient overvoltages, but repeated tests with identical waveforms can yield inconsistent results. As a result, standard impulse voltage waveforms are used for testing, defined by specific times...
174
Radial System Protection
125
Radial systems employ time-delay overcurrent relays to reduce load interruptions. When a fault occurs, the nearest breaker opens first, while upstream breakers remain closed due to longer delay settings. This approach ensures minimal disruption to the rest of the system.
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
125
Transmission Line Design Considerations
177
Aluminum has become the material of choice for overhead transmission lines, surpassing copper due to its abundance and cost-effectiveness. The most prevalent type is the aluminum conductor, steel-reinforced (ACSR), which combines aluminum strands around a steel core. Other variants include all-aluminum conductors (AAC), all-aluminum alloy conductors (AAAC), aluminum conductor alloy-reinforced (ACAR), and aluminum-clad steel conductors. Advanced designs, such as aluminum conductors with steel...
177
Fault Types
108
When analyzing a single line-to-ground fault from phase A to ground at a three-phase bus, it is important to consider the fault impedance. This impedance is zero for a bolted fault, equal to the arc impedance for an arcing fault, and represents the total fault impedance for a transmission-line insulator flashover. To derive sequence and phase currents, fault conditions are translated from the phase domain to the sequence domain.
For line-to-line faults occurring between phases B and C, the...
For line-to-line faults occurring between phases B and C, the...
108
Corrosion
25.2K
The degradation of metals due to natural electrochemical processes is known as corrosion. Rust formation on iron, tarnishing of silver, and the blue-green patina that develops on copper are examples of corrosion. Corrosion involves the oxidation of metals. Sometimes it is protective, such as the oxidation of copper or aluminum, wherein a protective layer of metal oxide or its derivatives forms on the surface, protecting the underlying metal from further oxidation. In other cases, corrosion is...
25.2K