海上MTDC传输扩张用于韩国电力系统的可再生能源扩展:DC高速公路
Junghun Lee1, Dongyeong Lee2, Jaehyeong Lee3
1Department of Electrical and Electronic Engineering, Korea University, Seoul, Korea.
概括
多终端直流 (MTDC) 系统可以将可再生能源整合到韩国电网中,减轻拥堵. 海上输电有效地转移可再生能源,确保电网稳定性和高效的能源利用.
科学领域:
- 电气工程 电气工程
- 电力系统工程 电力系统工程
- 整合可再生能源的整合
背景情况:
- 韩国电力系统中大规模的可再生能源整合预计将导致严重的线路拥堵,特别是在南部地区.
- 社会挑战阻碍了传统的交流输电线路的扩张,需要替代解决方案.
研究的目的:
- 分析多终端直流 (MTDC) 系统对将可再生能源资源整合到韩国电力系统的影响.
- 提出和评估一个离岸MTDC传输系统作为一个可行的解决方案,以减轻预期的电网拥堵.
主要方法:
- 使用年度风能和太阳能辐射数据计算有效的可再生能源发电能力.
- 电力系统模拟 (PSS/E) 模拟和最大限度地减少韩国电网未来的线路拥堵.
- 根据各种终端评级场景,验证一座离岸终端设计,用于从韩国转移电力.
主要成果:
- 模拟结果,包括应急分析,表明转移80%的可再生能源发电优化了线路流量条件.
- 拟议的海上MTDC系统有效地从南部可再生能源厂转移电力.
- 分析了不同的终端评级案例,以验证系统的性能.
结论:
- 多终端直流 (MTDC) 系统为将大量未来可再生能源容量集成到韩国电网提供了可行的解决方案.
- 离岸输电方法有效地解决了可再生能源整合和电网拥堵的挑战.
相关概念视频
Power System Distribution
273
Power system distribution involves delivering electrical energy from power plants to consumers through a network of transmission and distribution systems. The process begins at power plants, where energy from coal, gas, nuclear, water, and wind is converted into electrical energy. These plants use three-phase generators, typically rated between 50 to 1300 MVA, with terminal voltages ranging from a few kV to 20 kV, depending on the size and age of the units.
The transmission system is designed...
The transmission system is designed...
273
Transformers in Distribution System
127
Transformers in distribution systems can be broadly categorized into distribution substation transformers and other distribution transformers. They are crucial for stepping down high transmission voltages to levels suitable for distribution and end-user applications.
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
127
Fast Decoupled and DC Powerflow
241
The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
241
Power System Three-Phase Short Circuits
114
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
114
Primary Distribution
128
Primary distribution systems deliver electrical power from substations to consumers through various voltage classes, with 15-kV class voltages being predominant among U.S. utilities. Older 2.5- and 5-kV classes are being replaced by 15-kV primaries, while higher 25- to 34.5-kV classes are used in high-density urban areas and rural regions with long feeders. Three-phase, four-wire multigrounded systems are widely employed for balanced power delivery, using the neutral wire as a grounding point.
128
Maximum Power Flow and Line Loadability
140
The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
140