SKINNY-64.

Xing Fang1, Hongxin Zhang1,2, Xiaotong Cui1

  • 1School of Electronic Engineering, Beijing University of Posts and Telecommunications, Beijing 100876, China.

PubMed
概括

研究人员开发了一种高效的代数故障分析攻击SKINNY-64轻量级块密码. 这种方法可以使用最小的故障快速可靠地恢复主钥匙.

相关概念视频

SFG Algebra01:16

SFG Algebra

In Signal Flow Graph (SFG) algebra, the value a node represents is determined by the sum of all signals entering that node. This summed value is then transmitted through every branch leaving the node, making the SFG a powerful tool for visualizing and analyzing control systems.
Each node in an SFG corresponds to a variable, and the interactions between nodes are represented by branches with associated gains. When multiple branches lead into a node, the value at that node is the sum of the...
143
Unsymmetric Loading of Thin-Walled Members: Problem Solving01:07

Unsymmetric Loading of Thin-Walled Members: Problem Solving

The shear center of a channel section with uniform thickness, height, and width, is determined by computing the shear force in the member and calculating the moments of inertia of the sections.
To compute the shear forces, find the shear flow at a specific distance from the endpoint using the vertical shear and the moment of inertia values. The total shear force on the flange is calculated by integrating the shear flow from one end of the flange to the other.
Next, calculate the moments of...
134
Norton's Theorem01:14

Norton's Theorem

Norton's theorem is a fundamental principle stating that a linear two-terminal circuit can be substituted with an equivalent circuit, which comprises a current source (ⅠN) in parallel with a resistor (RN). Here, ⅠN represents the short-circuit current flowing through the terminals, and RN stands for the input or equivalent resistance at the terminals when all independent sources are deactivated. This implies that the circuit illustrated in Figure (a) can be exchanged with the...
648
Weak Base Solutions03:21

Weak Base Solutions

Some compounds produce hydroxide ions when dissolved by chemically reacting with water molecules. In all cases, these compounds react only partially and so are classified as weak bases. These types of compounds are also abundant in nature and important commodities in various technologies. For example, global production of the weak base ammonia is typically well over 100 metric tons annually, being widely used as an agricultural fertilizer, a raw material for chemical synthesis of other...
22.8K
Types of Errors: Detection and Minimization01:12

Types of Errors: Detection and Minimization

Error is the deviation of the obtained result from the true, expected value or the estimated central value. Errors are expressed in absolute or relative terms.
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...
1.7K
Fault Types01:18

Fault Types

When analyzing a single line-to-ground fault from phase A to ground at a three-phase bus, it is important to consider the fault impedance. This impedance is zero for a bolted fault, equal to the arc impedance for an arcing fault, and represents the total fault impedance for a transmission-line insulator flashover. To derive sequence and phase currents, fault conditions are translated from the phase domain to the sequence domain.
For line-to-line faults occurring between phases B and C, the...
108