使用弧形和非弧形关节器和全景放射图测量的条件导向角度的比较评估-系统性审查和元分析
Amjad Obaid Aljohani1, Mohammed Ghazi Sghaireen1, Muhammad Abbas1
1Department of Prosthodontics, College of Dentistry, Jouf University, Sakaka 72345, Saudi Arabia.
Life (Basel, Switzerland)
|June 28, 2023
概括
全景射线图对于测量状牙指导值 (CGVs) 比在假牙治疗中的关节器更有效. 弓形关节器显示的CGV略高于非弓形类型,但需要进一步研究.
科学领域:
- 牙科 牙科是指牙科的专业.
- 牙修复 牙修复 牙修复 牙修复 牙修复
- 生物医学工程 生物医学工程
背景情况:
- 线状指导值 (CGV) 的测量对于假牙治疗规划至关重要.
- 横向CGV (HCGV) 和横向CGV (LCGV) 是关键参数.
- 评估CGV测量协议对于临床实践至关重要.
研究的目的:
- 系统地审查和比较关节器 (弓形和非弓形) 和全景放射图的CGV测量的有效性.
- 为了确定哪种方法在各种参数中表现更好.
- 为牙套实践提供基于证据的见解.
主要方法:
- 对13项研究进行了系统审查和元分析.
- 通过使用MeSH术语和关键词搜索主要数据库,例如"弧形关","圆柱导向角度","非弧形关","全景X射线"和"放射性检查".
- 通过关节器和全景射线图获得的CGV测量结果进行比较.
主要成果:
- 全景射线图在CGV测量中表现出明显更高的疗效,与关器相比.
- 弓形关节器的CGV略高于非弓形关节器,这是由于优异的部运动模拟.
- 大多数研究都倾向于使用全景射线图进行CGV评估.
结论:
- 全景射线图是一种更有效的CGV测量方法.
- 关节器提供了更精确的模拟下巴运动.
- 需要进一步的研究来验证这些发现,并完善CGV测量协议以供临床应用.
相关概念视频
Relative Motion Analysis using Rotating Axes-Problem Solving
Consider a crane whose telescopic boom rotates with an angular velocity of 0.04 rad/s and angular acceleration of 0.02 rad/s2. Along with the rotation, the boom also extends linearly with a uniform speed of 5 m/s. The extension of the boom is measured at point D, which is measured with respect to the fixed point C on the other end of the boom. For the given instant, the distance between points C and D is 60 meters.
Here, in order to determine the magnitude of velocity and acceleration for point...
Here, in order to determine the magnitude of velocity and acceleration for point...
Distance Corrections
To achieve precise distance measurements, especially in surveying and construction, certain corrections must be applied to account for potential sources of error like the standardization errors, temperature variations, and slope adjustments.Standardization error emerges when measurement equipment undergoes changes, such as wear, repairs, or weather impacts. To address this, surveyors compare the equipment’s readings to a standard. This process identifies any deviation that might lead to...
Influence of Earth's Curvature and Atmospheric Refraction on Leveling
During leveling, the Earth's curvature and atmospheric refraction introduce deviations in the line of sight from a true horizontal reference. When the line of sight is leveled, it remains perpendicular to the plumb line only at a single point. Beyond this, it deviates due to the Earth’s curvature, represented by the correction C. For a sight distance D, the deviation can be derived using the relationship:This relationship shows that the deviation increases quadratically with distance. Over a...
Common Leveling Mistakes and Errors
A survey team is tasked with determining the elevation difference between points Point A and Point B, separated by uneven terrain. They use a leveling instrument and a leveling rod.Common MistakesMisreading the Rod: During a backsight reading at Point A, the instrumentman observes the rod partially obscured by tall grass. Instead of reading 1.135 m, they mistakenly record 1.735 m due to the misalignment of the crosshair with the wrong graduation. This error adds 0.600 m to all subsequent...
Design Example: Traverse Angle Computations
Traverse angle computations are a critical component of surveying, used to compute the internal angles within a closed traverse. A traverse consists of a series of connected lines forming a closed loop, often used for land boundary delineation or mapping. Calculating the internal angles ensures accuracy in the traverse geometry and is essential for checking survey data integrity.The process begins with known azimuths and bearings of the traverse sides. Internal angles at each vertex are...
Adjusting a Traverse
In the site survey of a four-sided traverse, internal angles are essential to ensure geometric accuracy. The survey revealed that the sum of the measured internal angles was 359 degrees and 48 minutes, which is 12 minutes less than the expected 360 degrees. This discrepancy signals an error likely arising from measurement inaccuracies during the fieldwork.To rectify this error, the adjustment process involved distributing the 12-minute shortfall equally across the four internal angles. By...


