概括
光污染会扭曲Fabry-Perot干扰仪 (FPI) 的气光数据,影响温度的准确性. 一种新的校正方法通过减少干扰图扭曲来提高温度反转的准确性,确保可靠的大气风和温度测量.
科学领域:
- 大气物理学 大气物理学
- 光学仪器仪器仪器仪器仪器仪器仪器仪器仪器仪器仪器仪器
- 地质物理学 地质物理学
背景情况:
- 法布里-佩罗干扰仪 (FPI) 对于大气风和温度测量至关重要.
- 来自路灯和月光等来源的光污染可以扭曲FPI空气发光干扰图.
- 干扰图的扭曲会对风和温度逆转的准确性产生负面影响.
研究的目的:
- 为了研究光污染对FPI空气发光干涉图的影响.
- 开发和验证用于扭曲的FPI干涉图的校正方法.
- 为了提高来自FPI数据的大气温度逆转的准确性.
主要方法:
- 在光污染条件下模拟FPI干扰图.
- 从完全和部分干扰图中逆转风和温度.
- 分析Kelan (38.7°N,111.6°E) 的真实空气发光干涉图.
- 开发一种校正方法,使扭曲的干涉图均化.
主要成果:
- 模拟和真实数据分析表明,干扰图的扭曲会导致温度偏差,但不会影响风力测量.
- 拟议的校正方法显著减少了扭曲的干涉图中的温度偏差.
- 校正后的分析表明,不同干扰图部分的风和温度误差减少了.
结论:
- 光污染是影响FPI温度测量的重要因素.
- 开发的校正方法有效地减轻了干扰图扭曲的影响.
- 这种技术提高了基于FPI的空气温度逆转在受污染的环境中的可靠性.
更多相关视频
06:46Applying X-ray Imaging Crystal Spectroscopy for Use as a High Temperature Plasma Diagnostic
Published on: August 25, 2016
11.4K
11:57Three-dimensional Super Resolution Microscopy of F-actin Filaments by Interferometric PhotoActivated Localization Microscopy iPALM
Published on: December 1, 2016
10.8K
相关概念视频
Influence of Earth's Curvature and Atmospheric Refraction on Leveling
153
During leveling, the Earth's curvature and atmospheric refraction introduce deviations in the line of sight from a true horizontal reference. When the line of sight is leveled, it remains perpendicular to the plumb line only at a single point. Beyond this, it deviates due to the Earth’s curvature, represented by the correction C. For a sight distance D, the deviation can be derived using the relationship:This relationship shows that the deviation increases quadratically with distance.
153
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
435
Attenuated total reflectance (ATR) infrared spectroscopy is a powerful analytical technique used to study the composition of materials. It is widely employed in chemistry, materials science, forensic science, and other fields where sample characterization is required. ATR has several advantages over traditional transmission IR spectroscopy, including the requirement of little to no sample preparation and the ability to analyze a wide range of samples.
The ATR process begins by directing a beam...
The ATR process begins by directing a beam...
435
Variation of Atmospheric Pressure
2.3K
Change in atmospheric pressure with height is particularly interesting. The decrease in atmospheric pressure with increasing altitude is due to the decreasing gravitational force per unit area as we move away from the surface of the earth.
Assuming the air temperature is constant at a given altitude and that the ideal gas law of thermodynamics describes the atmosphere to a good approximation, one can find the variation of atmospheric pressure with height.
Let p(y) be the atmospheric pressure at...
Assuming the air temperature is constant at a given altitude and that the ideal gas law of thermodynamics describes the atmosphere to a good approximation, one can find the variation of atmospheric pressure with height.
Let p(y) be the atmospheric pressure at...
2.3K
Precipitation Gravimetry
6.7K
Precipitation gravimetry is based on converting an analyte into a sparingly soluble precipitate, which is separated by filtration and weighed. An ideal precipitate should be pure, insoluble, of known composition, and easily filtered from the reaction mixture.
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...
6.7K
Isochoric and Isobaric Processes
3.5K
A thermodynamic process that occurs at constant volume is called an isochoric process. According to the first law of thermodynamics, heat supplied or removed from the system is partially utilized to perform work and change the internal energy of the system. However, in an isochoric process, the volume remains constant. Hence, the work done by the system is zero. Therefore, the exchange of heat changes the internal energy of the system only.
Suppose 1000 g of water is heated from 40...
Suppose 1000 g of water is heated from 40...
3.5K
IR Spectrometers
1.2K
There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
1.2K
