电力供应和婴儿死亡率的全国差异:来自加纳的证据
Mikidadu Mohammed1, Mathias Akuoko2
1Department of Economics & Business Administration, Austin College, 900 North Grand Avenue, Sherman, TX 75090, USA.
Health policy OPEN
|June 29, 2023
概括
加纳改善电力供应可在低风险地区显著降低婴儿死亡率. 然而,在高风险地区,仅仅是电力改进是不够的,需要综合健康基础设施开发才能产生影响.
科学领域:
- 公共卫生 公共卫生
- 社会经济学 社会经济学
- 环境健康 环境健康
背景情况:
- 在许多发展中国家,婴儿死亡率仍然是一个关键的公共卫生挑战.
- 对于有针对性的干预措施来说,了解在分国家级的婴儿死亡率的多方面的决定因素至关重要.
研究的目的:
- 调查加纳地区地区电力供应和婴儿死亡率之间的关系.
- 分析不同区域背景下的社会人口因素对婴儿死亡率的影响.
主要方法:
- 使用聚合的横截面回归分析.
- 从加纳人口和健康调查 (GDHS) 获得的数据涵盖了1993年至2014年的10个行政区域.
主要成果:
- 在低死亡率地区,增加10%的电力供应与每1000个活产婴儿死亡率减少11.8个相关.
- 在高死亡率地区,获得电力对婴儿死亡率没有显著影响.
- 诸如分娩间隔,父母同居,妇女教育和财富分配等因素在区域死亡率的基础上表现出差异性影响.
结论:
- 关于获得电力和婴儿死亡率的地方分析是富有成效的.
- 可靠的电力供应是必要的,但不够的;它必须与卫生基础设施的发展相结合,特别是在高婴儿死亡率的地区.
- 考虑到区域差异的定制政策干预措施对于降低婴儿死亡率至关重要.
更多相关视频
05:15Author Spotlight: Assessing the Feasibility of Using Amplitude-Integrated EEG During Neonatal Transport
Published on: June 21, 2024
753
03:35Determining Gender-Based Differences in Retinal and Choroidal Thickness in Underweight Individuals via Swept-Source Optical Coherence Tomography
Published on: December 1, 2023
337
相关概念视频
Secondary Distribution
110
Secondary distribution systems provide electrical energy at the utilization voltage levels from distribution transformers to customer meters. Typical secondary voltages in the United States include 120/240 V for residential use, 208Y/120 V for residential and commercial use, and 480Y/277 V for industrial and high-rise commercial use.
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
110
Primary Distribution
128
Primary distribution systems deliver electrical power from substations to consumers through various voltage classes, with 15-kV class voltages being predominant among U.S. utilities. Older 2.5- and 5-kV classes are being replaced by 15-kV primaries, while higher 25- to 34.5-kV classes are used in high-density urban areas and rural regions with long feeders. Three-phase, four-wire multigrounded systems are widely employed for balanced power delivery, using the neutral wire as a grounding point.
128
Electrical Power
3.1K
Electric power is the product of current and voltage, represented in units of joules per second, or watts. For example, cars often have one or more auxiliary power outlets with which you can charge a cell phone or other electronic devices. These outlets may be rated at 20 amps and 12 volts, so that the circuit can deliver a maximum power of 240 watts. Consider a 25 Watt bulb and a 60 Watt bulb. The conversion of electrical energy produces heat and light, while the kinetic energy lost by the...
3.1K
Power System Distribution
273
Power system distribution involves delivering electrical energy from power plants to consumers through a network of transmission and distribution systems. The process begins at power plants, where energy from coal, gas, nuclear, water, and wind is converted into electrical energy. These plants use three-phase generators, typically rated between 50 to 1300 MVA, with terminal voltages ranging from a few kV to 20 kV, depending on the size and age of the units.
The transmission system is designed...
The transmission system is designed...
273
Household Wiring And Electrical Safety
1.3K
Companies that supply power to most modern households use three conductors, typically called a three-wire line. While one is neutral, the other two are both at 120 V but with opposite polarity, giving a voltage of 240 V between them. With a three-wire line, high-power appliances that require 240 V, such as electric stoves and clothes dryers, are linked between the two hot lines. 120 V appliances can be connected between the neutral and either of the hot lines. The neutral side, which is always...
1.3K
Three-Phase Circuits
438
AC power distribution systems have three categories: single-phase, two-phase, and three-phase systems. The single-phase circuit, common in residential settings, typically employs a two-wire system connecting a single AC source to various loads. These circuits support standard household appliances operating at 120 volts (V) and 240 V, such as lamps, televisions, and microwaves. The first generators, Niagara Falls hydro plant installed in 1895, were two-phase and designed by Nikola Tesla. The...
438