概括
本研究介绍了一种简单的方法,以防止光学连贯性断层扫描 (OCT) 成像中的极化工件. 通过去极化光源,OCT信号保持不管样本的极化,提高图像质量.
科学领域:
- 生物医学光学 生物医学光学
- 医学成像技术 医学成像技术
- 光学工程的光学工程.
背景情况:
- 极化器件在光学连贯断层扫描 (OCT) 中很常见.
- 现代的OCT系统使用偏光,当光极化不匹配时会导致信号损失.
- 在OCT中交叉偏光不会干扰,导致像信号缺失这样的工件.
研究的目的:
- 介绍一种技术,以防止偏振工件在OCT.
- 为了确保不论样本极化状态,OCT信号检测的一致性.
- 为各种海外国家和地区设置提供一个具有成本效益的解决方案.
主要方法:
- 在干扰仪入口的光源部分去极化.
- 实施一种简单且具有成本效益的技术.
- 在定义的阻滞剂和硬质组织中测试该方法.
主要成果:
- 获得的OCT信号独立于样本的极化状态.
- 在受控和生物样本中证明有效的工件预防.
- 验证了该技术在双断层组织中的性能.
结论:
- 这种技术有效地消除了OCT的交叉极化工件.
- 这种简单的方法提高了不同样本类型的OCT图像可靠性.
- 这种方法广泛适用于不同的国家和地区的系统设计.
相关概念视频
Insensitive Nuclei Enhanced by Polarization Transfer (INEPT)
408
Insensitive Nuclei Enhanced by Polarization Transfer (INEPT) is an advanced Nuclear Magnetic Resonance (NMR) technique specifically designed to detect and enhance the signals of low-abundance nuclei, such as carbon-13 and nitrogen-15, in small molecules. The fundamental principle behind INEPT is the transfer of polarization from a more abundant and highly polarizable nucleus, typically hydrogen-1, to the low-abundance nucleus of interest. This process effectively boosts the NMR signal of the...
408
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)
1.1K
When proton-coupled carbon-13 spectra are simplified by a broadband proton decoupling technique, structural information about the coupled protons is lost. Distortionless enhancement by polarization transfer (DEPT) is a technique that provides information on the number of hydrogens attached to each carbon in a molecule. While the DEPT experiment utilizes complex pulse sequences, the pulse delay and flip angle are specifically manipulated. The resulting signals have different phases depending on...
1.1K
Dielectric Polarization in a Capacitor
4.8K
The presence of a dielectric medium in a capacitor not only changes the voltage and capacitance but also affects the electric field. In general, dielectrics can be of two types: polar and nonpolar. In a polar dielectric, the positive and negative charges in the molecules are separated by a distance and hence have a permanent dipole moment. In contrast, no such charge separation exists in a nonpolar dielectric, however the nonpolar molecules get polarized in the presence of an external electric...
4.8K
Group Polarization
34.4K
Group polarization is the strengthening of an original group attitude following the discussion of views within a group (Teger & Pruitt, 1967). That is, if a group initially favors a viewpoint, after discussion the group consensus is likely a stronger endorsement of the viewpoint. Conversely, if the group was initially opposed to a viewpoint, group discussion would likely lead to stronger opposition.
34.4K
Potential Due to a Polarized Object
439
A neutral atom consists of a positively charged nucleus surrounded by a negatively charged electron cloud. When placed in an external electric field, the external electric force pulls the electrons and nucleus apart, opposite to the intrinsic attraction between the nucleus and the electrons. The opposing forces balance each other with a slight shift between the center of masses of the nucleus and the electron cloud, resulting in a polarized atom. On the other hand, a few molecules, like water,...
439
Phase Contrast and Differential Interference Contrast Microscopy
8.2K
Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
8.2K