枪支检查人员对比决策的重复性和可复制性
Keith L Monson1, Erich D Smith1, Eugene M Peters1
1Federal Bureau of Investigation Laboratory, Quantico, Virginia, USA.
Journal of forensic sciences
|July 2, 2023
概括
法医枪支检查人员在识别匹配的子弹和弹的情况下表现出可靠的性能,具有高可重复性和可重复性,超过了偶然的协议. 意见分歧往往涉及不确的结果,而不是错误的识别或排除.
科学领域:
- 法医科学 法医科学 法医科学
- 枪支检查 枪支检查 枪支检查
- 弹道学 弹道学 弹道学
背景情况:
- 合格的法医枪支检查员的表现对司法系统至关重要.
- 评估枪支检查的准确性和一致性是一个正在进行的研究领域.
研究的目的:
- 通过合格的考核人员评估枪支检查的可重复性和可重复性.
- 通过使用枪支和工具标志检查员协会 (AFTE) 范围的结论来评估检查员决定的可靠性.
主要方法:
- 志愿者检查人员比较了三种枪支类型的子弹和弹.
- 再次提交比较集以评估可重复性和可复制性.
- 用AFTE范围的结论和两个假设的评分系统来分析数据.
主要成果:
- 已知匹配的重复率为78.3%,已知不匹配的重复率为64.5%.
- 已知匹配的可复制性为67.3%,已知不匹配的可复制性为36.5%.
- 经常在确定的和不确定的类别之间存在分歧.
结论:
- 枪支检查员的决定是可靠和值得信赖的.
- 对不匹配的项目不太可能进行识别,对匹配的项目不太可能进行删除.
- 该研究证实了枪支检查结果的一致性.
相关概念视频
Accuracy and Precision
9.9K
Scientists typically make repeated measurements of a quantity to ensure the quality of their findings and to evaluate both the precision and the accuracy of their results. Measurements are said to be precise if they yield very similar results when repeated in the same manner. A measurement is considered accurate if it yields a result that is very close to the true or the accepted value. Precise values agree with each other; accurate values agree with a true value. Highly accurate...
9.9K
Uncertainty in Measurement: Accuracy and Precision
74.0K
Scientists typically make repeated measurements of a quantity to ensure the quality of their findings and to evaluate both the precision and the accuracy of their results. Measurements are said to be precise if they yield very similar results when repeated in the same manner. A measurement is considered accurate if it yields a result that is very close to the true or the accepted value. Precise values agree with each other; accurate values agree with a true value.
74.0K
Statistical Analysis: Overview
6.7K
When we take repeated measurements on the same or replicated samples, we will observe inconsistencies in the magnitude. These inconsistencies are called errors. To categorize and characterize these results and their errors, the researcher can use statistical analysis to determine the quality of the measurements and/or suitability of the methods.
One of the most commonly used statistical quantifiers is the mean, which is the ratio between the sum of the numerical values of all results and the...
One of the most commonly used statistical quantifiers is the mean, which is the ratio between the sum of the numerical values of all results and the...
6.7K
Reliability and Validity
12.8K
Reliability and validity are two important considerations that must be made with any type of data collection. Reliability refers to the ability to consistently produce a given result. In the context of psychological research, this would mean that any instruments or tools used to collect data do so in consistent, reproducible ways.
12.8K
Random and Systematic Errors
11.1K
Scientists always try their best to record measurements with the utmost accuracy and precision. However, sometimes errors do occur. These errors can be random or systematic. Random errors are observed due to the inconsistency or fluctuation in the measurement process, or variations in the quantity itself that is being measured. Such errors fluctuate from being greater than or less than the true value in repeated measurements. Consider a scientist measuring the length of an earthworm using a...
11.1K
Systematic Error: Methodological and Sampling Errors
1.5K
In the case of systematic errors, the sources can be identified, and the errors can be subsequently minimized by addressing these sources. According to the source, systematic errors can be divided into sampling, instrumental, methodological, and personal errors.
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
1.5K