血压对脑组织脉冲振幅的影响 幻影模型
Jennifer K Nicholls1, Poppy Turner2, Andrea Lecchini-Visintini3
1Cerebral Haemodynamics in Ageing and Stroke Medicine (CHiASM) Research Group, Department of Cardiovascular Sciences, University of Leicester, Leicester, UK; Department of Medical Physics, University Hospitals of Leicester NHS Trust, Leicester, UK.
Ultrasound in medicine & biology
|July 3, 2023
概括
大脑组织脉冲 (BTPs) 的幅度随着脉冲压 (PP) 显著增加,但不是平均动脉压 (MAP). 每增加PP的1mmHg,BTP的幅度都会增加0.29μm,为脑血管动力学提供新的见解.
科学领域:
- 生物医学工程 生物医学工程
- 神经科学是一个神经科学.
- 心血管生理学心血管生理学
背景情况:
- 驱动脑组织脉 (BTP) 的机制和血压 (BP) 的影响仍然不清楚.
- 了解BTP对于评估脑血管健康至关重要.
研究的目的:
- 为了研究血压参数 (平均动脉压[MAP]和脉冲压[PP]) 和BTP振幅之间的关系.
- 量化MAP和PP对BTP的影响.
主要方法:
- 开发了一个幻脑模型来模拟动脉诱导的BTPs.
- 用了一种跨组织多普勒原型进行BTP测量.
- 使用回归模型分析BTP幅度与BP变化相关,隔离MAP和PP效应.
主要成果:
- 在BTP振幅和PP之间发现了强烈的相关性 (R2 = 0.978).
- 随着PP的上升,BTP振幅显著增加,但与MAP并非如此.
- 在PP增加1mmHg对应于0.29μm增加的批量BTP振幅.
结论:
- 血压增加与增加的批量BTP振幅有显著的关联.
- 脉冲压是BTP振幅的一个关键决定因素.
- 未来的研究应该在有大脑自我调节和其他生理因素的条件下探索BTP.
相关概念视频
Measurement of Blood Pressure
1.0K
Assessing blood pressure is a standard procedure executed in virtually all medical environments. The method utilized today was established over a hundred years ago by an innovative Russian doctor, Dr. Nikolai Korotkoff. The soft ticking noise, known as Korotkoff sounds, heard while taking blood pressure readings results from turbulent blood flow within the vessels. The apparatus required for this procedure includes a sphygmomanometer, a blood pressure cuff attached to a gauge, and a...
1.0K
Blood Pressure
3.2K
The movement of blood in a human body, commonly referred to as blood flow, is determined by the volume of blood that traverses a certain section of the bodily system per unit time. It is the rhythmic contraction of the heart's ventricles that primarily instigates this movement. As the ventricles contract, blood is forced into the prominent arteries, which then flow from areas of greater pressure to lower pressure areas. This movement continues into smaller arteries and arterioles and...
3.2K
Special considerations while measuring blood pressure
765
When assessing blood pressure (BP), healthcare professionals must consider various factors and potential unexpected outcomes to ensure accurate readings and provide proper patient care. Adhering to these guidelines is essential to achieving the most reliable results.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
765
Sites for measruring blood pressure
1.9K
Blood pressure measurement is a fundamental clinical procedure, providing crucial data for assessing cardiovascular health. Among the various sites for this measurement, the brachial and popliteal arteries are predominantly utilized due to their accessibility and the reliability of their readings. This lesson delves into the anatomical significance, methodology, and considerations of measuring blood pressure at these locations.
The Brachial Artery: Primary Site for Blood Pressure Measurement
The Brachial Artery: Primary Site for Blood Pressure Measurement
1.9K
Equipments Used To Measure Blood Pressure
1.1K
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
1.1K
Pre-Procedural Guidelines for Assessing Blood Pressure
596
Accurate blood pressure assessment is crucial for diagnosing and managing various health conditions. To ensure the reliability of these measurements, healthcare professionals must adhere to standardized pre-procedural guidelines. These guidelines enhance patient safety and improve the overall quality of healthcare. The following steps are essential for obtaining accurate and consistent blood pressure readings, from using the appropriate tools to ensuring effective communication with the...
596