∆8-THC-COOH与大麻素免疫测试工具的交叉反应性以及对色谱测试方法的干扰
Lawrance D Mullen1, E Dale Hart1, Svante Vikingsson1
1Center for Forensic Science Advancement and Application, RTI International, 3040 East Cornwallis Rd., Research Triangle Park, NC 27709, USA.
Journal of analytical toxicology
|July 5, 2023
概括
11-Nor-9-carboxy-∆8-tetrahydrocannabinol (∆8-THC-COOH) 和11-Nor-9-carboxy-∆9-tetrahydrocannabinol (∆9-THC-COOH) 之间的结构相似性可能会导致药物测试中的干扰. 虽然没有报告虚假阳性,但在确认测试期间发生了不可报告的结果.
科学领域:
- 法医毒理学 法医毒理学
- 分析化学 分析化学
背景情况:
- ∆8-THC-COOH和∆9-THC-COOH之间的结构相似性可以导致免疫试验中的交叉反应性.
- 准确的药物测试对于工作场所的安全和法律遵守至关重要.
研究的目的:
- 调查∆8-THC-COOH在∆9-THC-COOH的免疫试验和确认测试中的潜在干扰.
- 评估∆8-THC-COOH对大麻代谢物工作场所药物测试准确性的影响.
主要方法:
- 来自三家制造商的免疫试验试剂被用于测试不同切断点的不同度的∆8-THC-COOH样品.
- 在HHS认证的实验室中,使用常见的确认方法分析了含有∆8-THC-COOH和∆9-THC-COOH的强化样本.
主要成果:
- ∆8-THC-COOH的交叉活性在三种免疫测试平台的切断值为50 ng/mL,范围为87%至112%.
- 在存在∆8-THC-COOH时对∆9-THC-COOH进行确认测试,由于染色学干扰或质量比失败,导致无法报告的发现.
- 没有任何HHS认证的实验室报告任何虚假阳性∆9-THC-COOH结果.
结论:
- ∆8-THC-COOH可以干扰免疫检测查和∆9-THC-COOH的确认测试.
- 虽然∆8-THC-COOH没有导致错误阳性,但它可能导致确认分析中无法报告的结果,这可能会影响药物测试的解释.
- 在法医毒理学中,可能需要进一步开发方法来区分∆8-THC-COOH和∆9-THC-COOH.
相关概念视频
Chemotherapy-Induced Nausea and Vomiting: Cannabinoids
324
Tetrahydrocannabinol (THC) is a phytocannabinoid that primarily interacts with the CB1 receptor, a type of G protein-coupled receptor (GPCR) predominantly in and around the chemoreceptor trigger zone (CTZ) and emetic center. THC also blocks the serotonin receptor activity in the dorsal vagal complex (DVC) by inhibiting serotonin release. THC exerts its anti-emetic effects through these interactions, which are beneficial for patients undergoing chemotherapy.
Two synthetic agonists of THC,...
Two synthetic agonists of THC,...
324
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
525
Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and...
525
Atomic Absorption Spectroscopy: Interference
854
Interference leads to systematic error in atomic absorption (AA) measurements by enhancing or diminishing the analytical signal or the background. These interferences can be grouped into three main categories: spectral interference, chemical interference, and physical interference.
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
854
Cross-reactivity
31.3K
Overview
31.3K