相关实验视频
Updated: Jul 24, 2025

08:29
Thermal Measurement Techniques in Analytical Microfluidic Devices
Published on: June 3, 2015
9.7K
一个基于微热电发生器的新型热触摸传感器,用于水下流动方向感知
Changxin Liu1, Nanxi Chen1, Guangyi Xing1
1Dalian Key Lab of Marine Micro/Nano Energy and Self-Powered Systems, Marine Engineering College, Dalian Maritime University, Dalian 116026, China.
Sensors (Basel, Switzerland)
|July 8, 2023
概括
一种新的水下流动方向传感方法使用微热电发生器 (MTEG) 来克服海洋资源勘探中的挑战. 这种具有成本效益的MTEG技术为水下车辆提供了实际应用.
科学领域:
- 机器人技术和自主系统
- 海洋工程 海洋工程
- 传感器技术 传感器技术
背景情况:
- 水下车辆面临水流干扰的挑战,影响海洋资源开发.
- 现有的水下流动方向传感方法昂贵,难以与车辆集成.
研究的目的:
- 提出和验证一种使用微热电发生器 (MTEG) 的新水下流动方向传感方法.
- 开发一个具有成本效益和易于集成的解决方案,用于水下流感知.
主要方法:
- 建立了基于MTEG热触感的流向传感理论模型.
- 制造了一个原型,并在三个不同的流量条件下进行了实验 (平行,45°和可变).
- 对实验输出电压验证了理论模型.
主要成果:
- 实验数据证实,原型的输出电压与理论模型保持一致.
- 原型在02秒内准确识别了流动方向,速度为05米/秒,角度为090°.
- 与传统方法相比,MTEG方法显示出更高的成本效益和更容易整合.
结论:
- 拟议的基于MTEG的方法是用于水下流动方向传感的可行和实际解决方案.
- 这项技术在增强水下车辆的能力方面具有显著的应用前景.
- 该MTEG系统可以使用水下车辆电池的废热进行自动供电,从而增加其效用.
相关概念视频
Thermosensation
30.5K
Peripheral thermosensation is the perception of external temperature. A change in temperature (on the surface of the skin and other tissues) is detected by a family of temperature-sensitive ion channels called Transient Receptor Potential, or TRP, receptors. These receptors are located on free nerve endings. Those detecting cold temperatures are closer to the surface of the skin than the nerve endings detecting warmth. These thermoTRP channels, while temperature selective, have relatively...
30.5K
Assessing Body Temperature - Tympanic membrane
625
Assessing tympanic membrane temperature involves using a tympanic membrane thermometer (TMT). Here is a step-by-step guide:
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
625
Equipments Used to Measure Body Temperature
1.1K
Body temperature can be assessed using various devices and measured in Celsius or Fahrenheit.
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
1.1K
Assessing Body Temperature - Temporal Artery
594
Here is a stepwise guide to assessing the body temperature at the temporal artery using a temporal artery thermometer
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
594