在LEO卫星网络中用于回程的新料链接交付策略
Yuke Zhou1, Jiang Liu1,2, Ran Zhang1,2
1State Key Laboratory of Networking and Switching Technology, Beijing University of Posts and Telecommunications, Beijing 100876, China.
Sensors (Basel, Switzerland)
|July 8, 2023
概括
低地轨道 (LEO) 卫星网络提供全球宽带,但面临交付中断. 一项新的战略通过考虑链路质量和网络状态来最大限度地提高后续运输能力,减少交付频率以提高性能.
科学领域:
- 电信 电信服务 电信服务 电信服务
- 卫星通信 卫星通信
- 网络工程 网络工程
背景情况:
- 低地轨道 (LEO) 卫星网络对于全球宽带回程至关重要.
- 在LEO网络中频繁的料链接交接会导致通信中断,并降低后网质量.
研究的目的:
- 提出交付策略,最大限度地提高LEO卫星网络的回程能力.
- 为了减少交付频率,同时保持高质量的回程运输.
主要方法:
- 设计了一个"可用的后载运输能力比率",考虑到料链路质量和卫星间网络状态.
- 引入了"服务时间因子"和"交付控制因子",以尽量减少交付频率.
- 开发了一个移交公用事业功能,并实施了一个基于贪的移交策略.
主要成果:
- 与传统方法相比,拟议的战略显著提高了回程运输能力.
- 该策略有效地减少了移交的频率.
- 模拟结果验证了在容量和交付减少方面提高的性能.
结论:
- 开发的最大后续运输能力交付战略解决了LEO卫星网络的关键挑战.
- 这种方法为移动宽带和物联网回程提供了卓越的解决方案.
- 该战略平衡了能力提升与减少交付频率,以实现可靠的LEO通信.
相关概念视频
Transmission Line Design Considerations
172
Aluminum has become the material of choice for overhead transmission lines, surpassing copper due to its abundance and cost-effectiveness. The most prevalent type is the aluminum conductor, steel-reinforced (ACSR), which combines aluminum strands around a steel core. Other variants include all-aluminum conductors (AAC), all-aluminum alloy conductors (AAAC), aluminum conductor alloy-reinforced (ACAR), and aluminum-clad steel conductors. Advanced designs, such as aluminum conductors with steel...
172
Load-frequency control
197
Load-frequency control (LFC) is vital for maintaining power system stability, ensuring that frequency and power flows remain within acceptable limits during load changes. Turbine-governor control eliminates rotor accelerations and decelerations following load changes. However, a steady-state frequency error persists when the change in the turbine-governor reference setting is zero. In an interconnected power system, each area agrees to export or import a scheduled amount of power through...
197
Cable Subjected to a Distributed Load
736
The analysis of suspension bridges is a complex and critical process that involves multiple factors, including the shape and tension of the main cables. The main cables of suspension bridges are subjected to distributed loads, which result in changes in tensile forces and deformation of the cable. These loads must be carefully considered to ensure that the bridge is safe and capable of supporting the weight of different loads.
736
Maximum Power Transfer
292
Numerous practical applications within engineering disciplines, such as telecommunications, necessitate optimizing power delivery to a connected load. This pursuit, however, entails inherent internal losses, which can either equal or exceed the power supplied to the load. The Thevenin equivalent circuit is helpful in finding the maximum power a linear circuit can deliver to a load. It is assumed in this context that the load resistance can be adjusted.
By substituting the entire circuit with...
By substituting the entire circuit with...
292
Reducing Line Loss
174
In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...
174
Pilot and Numeric Relaying
105
Pilot relaying is a type of differential protection used in power systems. It compares electrical quantities at the terminals of equipment via a communication channel instead of direct relay interconnection. This method is essential for transmission lines where the terminals are far apart, typically up to 80 km for lines with 69 to 115 kV ratings. Four types of communication channels are used for pilot relaying:
105


