概括
优化射频 (RF) 线圈可提高磁共振成像 (MRI) 和光谱 (MRS) 中的信号噪声比 (SNR). 本综述涵盖了估计和最小化RF线圈中导体损失的方法,以提高MRI/MRS数据质量.
科学领域:
- 医学成像物理 医学成像物理
- 电气工程 电气工程
- 生物物理学的生物物理.
背景情况:
- 优化的射频 (RF) 线圈设计对于最大限度地提高磁共振成像 (MRI) 和磁共振光谱 (MRS) 中的信号噪声比 (SNR) 是至关重要的.
- 线圈导体阻力引入噪声,通过降低SNR降低数据质量,特别是在较低的频率.
- 导体损耗受到频率 (皮肤效应) 和导体几何 (条纹与线材) 的影响.
研究的目的:
- 审查用于MRI/MRS的射频线圈中导体损失估计的方法.
- 描述减少这些损失的策略.
- 简要介绍射频线圈设计中的新兴技术.
主要方法:
- 检查用于导体损失估计的分析配方.
- 讨论理论/实验混合方法.
- 对于损失分析的全波模拟技术的概述.
主要成果:
- 确定了影响导体损失的关键因素:频率和导体形状.
- 介绍了各种减轻导体损失的策略.
- 强调了相对于采样噪声来说,尽量减少线圈噪声的重要性.
结论:
- 准确估计和最小化导体损失对于高质量的MRI/MRS数据至关重要.
- 利茨线,冷却和超导等技术为减少损失提供了解决方案.
- 射频线圈设计的进步继续提高MRI/MRS性能.
相关概念视频
Magnetic Resonance Imaging
5.3K
Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...
5.3K
Equivalent Circuits for Practical Transformers
472
The practical equivalent circuits of single-phase two-winding transformers exhibit significant deviations from their idealized versions due to the inherent properties of winding resistance and finite core permeability. These properties result in real and reactive power losses, affecting the transformer's performance. Understanding these deviations is crucial for designing more efficient transformers.
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
472
Magnetic Field Due To A Thin Straight Wire
4.9K
Consider an infinitely long straight wire carrying a current I. The magnetic field at point P at a distance a from the origin can be calculated using the Biot-Savart law.
4.9K
Energy Losses in Transformers
907
In an ideal transformer, it is assumed that there are no energy losses, and, hence, all the power at the primary winding is transferred to the secondary winding. However, in reality, the transformers always have some energy losses, and, hence, the output power obtained at the secondary winding is less than the input power at the primary winding due to energy losses.
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
907
Imaging Studies for Cardiovascular System IV: CMRI
65
Cardiovascular magnetic resonance imaging, or CMRI, is a non-invasive diagnostic test that employs a magnetic field and radiofrequency waves to create precise images of the heart and arteries. It provides comprehensive information about cardiac anatomy, function, perfusion, and tissue characterization without ionizing radiation.IndicationsCMRI diagnoses various heart conditions, including tissue damage from heart attacks, ischemic heart disease, myocarditis, aortic issues (tears, aneurysms,...
65
Toroids
3.0K
A toroid is a closely wound donut-shaped coil constructed using a single conducting wire. In general, it is assumed that a toriod consists of multiple circular loops perpendicular to its axis.
When connected to a supply, the magnetic field generated in the toroid has field lines circular and concentric to its axis. Conventionally, the direction of this magnetic field is expressed using the right-hand rule. If the fingers of the right hand curl in the current direction, the thumb...
When connected to a supply, the magnetic field generated in the toroid has field lines circular and concentric to its axis. Conventionally, the direction of this magnetic field is expressed using the right-hand rule. If the fingers of the right hand curl in the current direction, the thumb...
3.0K