相关实验视频
Updated: Jul 24, 2025

08:20
In Situ Soil Moisture Sensors in Undisturbed Soils
Published on: November 18, 2022
6.3K
研究煤矿固体填充工作面部传感系统的数据有效性,该系统基于改进的变压器
Lei Bo1, Shangqing Yang1, Yang Liu1
1School of Mechanical Electronic and Information Engineering, China University of Mining and Technology (Beijing), Beijing, 100083, China.
Scientific reports
|July 8, 2023
概括
本研究介绍了物联网 (IoT) 框架,用于煤矿的固体填充,改进数据收集并实现实时监控. 基于变压器的异常检测模型以90%的准确性确保了数据的有效性.
科学领域:
- 采矿工程 采矿工程 采矿工程
- 数据科学数据科学数据科学
- 物联网 (IoT) 的物联网 (IoT) 的物联网.
背景情况:
- 固体回填对于煤矿安全和环境遵守至关重要.
- 传统方法受到有限的数据,孤立的传感器的影响,并阻碍了智能流程的开发.
- 实时监控和智能流程开发目前是有限的.
研究的目的:
- 为固体填充作业提出一个感知网络框架.
- 解决煤矿回填数据采集和有效性方面的挑战.
- 开发一个智能系统,以加强监控和过程控制.
主要方法:
- 在回填过程中分析批判性感知对象.
- 煤矿填充物联网 (IoT) 感知网络和功能框架的开发.
- 实现基于变压器的异常检测模型用于数据验证.
主要成果:
- 拟议的框架有助于将关键感知数据快速集中到一个统一的数据中心.
- 基于变压器的异常检测模型在识别数据异常方面实现了90%的准确性.
- 该模型表现出良好的概括能力,用于监测增加的感知对象.
结论:
- 开发的感知网络框架增强了对固体填充作业的数据收集.
- 异常检测模型有效地确保了感知数据的有效性.
- 拟议的系统支持智能流程开发和实时监控煤矿回填.
相关概念视频
Instrument Transformers
108
Instrument transformers, comprising voltage transformers (VTs) and current transformers (CTs), play crucial roles in power substations by providing isolated replicas of current or voltage for measurement and protection purposes. Voltage transformers reduce the primary voltage to levels suitable for relay operation and measurement, while current transformers scale down the primary current. The primary winding of a current transformer often consists of a single turn, achieved by threading the...
108
Three-Winding Transformers
269
Three identical single-phase transformers can be configured to form a three-phase transformer connection, which involves high-voltage and low-voltage windings. The high-voltage windings are denoted by capital letters A-B-C, while the low-voltage windings are labeled with lowercase letters a-b-c, representing their respective phases. This notation helps distinguish between the high and low voltage sides of the transformer.
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
269
Transformers in Distribution System
127
Transformers in distribution systems can be broadly categorized into distribution substation transformers and other distribution transformers. They are crucial for stepping down high transmission voltages to levels suitable for distribution and end-user applications.
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
127
Equivalent Circuits for Practical Transformers
472
The practical equivalent circuits of single-phase two-winding transformers exhibit significant deviations from their idealized versions due to the inherent properties of winding resistance and finite core permeability. These properties result in real and reactive power losses, affecting the transformer's performance. Understanding these deviations is crucial for designing more efficient transformers.
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
472
Energy Losses in Transformers
907
In an ideal transformer, it is assumed that there are no energy losses, and, hence, all the power at the primary winding is transferred to the secondary winding. However, in reality, the transformers always have some energy losses, and, hence, the output power obtained at the secondary winding is less than the input power at the primary winding due to energy losses.
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
907