相关实验视频
Updated: Jul 24, 2025

16:11
Implementation of a Reference Interferometer for Nanodetection
Published on: April 26, 2014
9.4K
关于在亚毫赫兹频率下电压参考噪声的研究,用于开发超稳定的温度测量子系统
Lingyun Gu1, Houyuan Chen1, Peng Liu2
1School of Physics and Astronomy, Sun Yat-sen University, Zhuhai 519082, China.
Sensors (Basel, Switzerland)
|July 11, 2023
概括
这项研究引入了一种新的方法来测量电压参考 (VR) 芯片噪声到0.1mHz,这对于太空引力波检测至关重要. 结果显示,VR芯片中的低频噪声存在显著差异.
科学领域:
- 天体物理学和太空科学 天体物理学和太空科学
- 仪器仪表和测量仪器的使用
背景情况:
- 准确的温度监测对于太空引力波探测平台至关重要.
- 电压参考 (VRs) 是温度测量子系统 (TMS) 的关键组件.
- 虚拟现实机的低频噪声 (0.1mHz-1Hz) 是至关重要的,但研究不足.
研究的目的:
- 开发和验证一个双通道测量方法,用于亚毫赫兹的VR噪声.
- 为了描述最先进的VR芯片的低频噪声性能.
主要方法:
- 用于高灵敏度测量,采用了一种双通道切割器放大器.
- 使用组装隔热盒来最大限度地减少环境干扰.
- 测量结果达到3×10-7/Hz1/2在0.1mHz的正常分辨率.
主要成果:
- 开发的方法成功地测量了VR芯片噪声到0.1mHz.
- 测试了七个高性能VR芯片,揭示了在亚毫赫兹频率的显著噪声变化.
- 在亚毫赫兹频率的VR芯片噪声可能与1Hz左右的噪声水平有很大差异.
结论:
- 该研究提供了关于VR低频噪声的基本数据,用于引力波检测.
- 开发的测量技术为关键应用中的VR噪声提供了一种可靠的方法.
- 了解和减轻亚毫赫兹的VR噪声是提高敏感实验中温度测量精度的关键.
相关概念视频
Temperature Measurement Sites
1.8K
A thermometer measures body temperature. The common sites for measuring body temperature are the oral cavity, axillary region, temporal artery, and skin surface, such as the forehead, abdomen, and axilla. True core body temperature is assessed in the rectum, tympanic membrane, pulmonary artery, esophagus, and urinary bladder.
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
1.8K
Chemical Shift: Internal References and Solvent Effects
678
In an NMR sample, precise measurement of the absolute absorption frequencies of nuclei is difficult. A standard internal reference compound is added, and the frequency difference between the reference signal and sample signals is measured.
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
678
Voltage Dividers
553
In electrical circuits, resistors can be connected in series, sequentially linked one after the other. In a series configuration, the same current flows through each resistor. Ohm's law is a fundamental principle to understand the behavior of resistors in series. It expresses the voltage across these resistors in terms of the current and resistance.
Kirchhoff's voltage law implies that the sum of the voltages across the resistors in series equals the source voltage. This means that the...
Kirchhoff's voltage law implies that the sum of the voltages across the resistors in series equals the source voltage. This means that the...
553
Uncertainty in Measurement: Reading Instruments
38.3K
Counting is the type of measurement that is free from uncertainty, provided the number of objects being counted does not change during the process. Such measurements result in exact numbers. By counting the eggs in a carton, for instance, one can determine exactly how many eggs are there in the carton. Similarly, the numbers of defined quantities are also exact. For example, 1 foot is exactly 12 inches, 1 inch is exactly 2.54 centimeters, and 1 gram is exactly 0.001 kilograms. Quantities...
38.3K
Voltammetry: Factors Affecting Measurements
181
A current produced due to the redox reactions of the analyte at the working and auxiliary electrodes is called a faradaic current. The reaction can be divided into two types. The current generated due to the reduction of the analyte is called cathodic current, and it carries a positive charge. In contrast, the current produced by analyte oxidation is known as an anodic current, and it has a negative charge. The applied potential at the working electrode determines the faradaic current flow, and...
181
Thermometers and Temperature Scales
5.6K
Any physical property that depends consistently and reproducibly on temperature can be used as the basis of a thermometer. For example, volume increases with temperature for most substances. This property is the basis for the common alcohol thermometer and the original mercury thermometers. Other properties used to measure temperature include electrical resistance, color, and the emission of infrared radiation.
As many physical properties depend on temperature, the variety of thermometers is...
As many physical properties depend on temperature, the variety of thermometers is...
5.6K