相关实验视频
Updated: Jul 23, 2025

05:36
Subjective Refraction Test Using a Smartphone for Vision Screening
Published on: October 18, 2024
856
对于耳鼻病的使用Microguide手机应用程序:国家审查
Emily Wilson1, Alexia Dimitriou1, Amberley Munnings1
1Department of ENT, Milton Keynes University Hospital, Milton Keynes, UK.
The Journal of laryngology and otology
|July 12, 2023
概括
通过在Microguide智能手机应用程序中列出的ENT条件的标准化,可以改善医院的抗菌管理. 这项研究在123家医院中发现了所列病症的显著差异.
科学领域:
- 医疗保健技术 医疗保健技术 医疗保健技术
- 抗微生物药物管理管理
- 耳鼻喉科 耳鼻喉科 耳鼻喉科
背景情况:
- 像Microguide这样的智能手机应用程序在医疗保健中越来越多地用于抗菌指导.
- 然而,它们用于耳鼻喉 (ENT) 疾病的应用尚未先前审查.
研究的目的:
- 审查医院对耳鼻腔疾病的使用Microguide智能手机应用程序.
- 在不同机构中确定申请中列出的ENT条件的范围和一致性.
主要方法:
- 通过使用Microguide应用程序对所有医院账户进行了全面分析.
- 这项研究专门检查并列出了这些医院账户中记录的 ENT 条件.
主要成果:
- 该研究包括来自123家医院的数据.
- 在所有参与的医院中,共发现了45种与ENT相关的疾病.
- 平均而言,每家医院在其微指南账户中列出了8种耳鼻喉疾病,这表明存在显著的变化.
结论:
- 在医院之间,在Microguide应用程序中记录的ENT条件中存在显著的差异.
- 建议为Microguide提供推的ENT条件的标准化列表.
- 实施标准化清单可以加强在ENT部门内的抗菌药物管理.
相关概念视频
Assessing Body Temperature - Tympanic membrane
625
Assessing tympanic membrane temperature involves using a tympanic membrane thermometer (TMT). Here is a step-by-step guide:
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
625
Assessing Body Temperature - Oral
779
Here are the steps to accurately measure oral temperature using an electronic thermometer:
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
779

