从纠正维护到预测维护 - - 对电力行业的维护方法的审查
Marek Molęda1, Bożena Małysiak-Mrozek2, Weiping Ding3
1TAURON Wytwarzanie S.A., Promienna 51, 43-603 Jaworzno, Poland.
Sensors (Basel, Switzerland)
|July 14, 2023
概括
本综述探讨了工业设备的维护,从传统方法到人工智能驱动的分析. 它强调了电力部门预测性维护方面的进展,旨在减少昂贵的停机时间并指导未来的研究.
科学领域:
- 工程 工程师 工程师 工程师
- 计算机科学 计算机科学
- 数据科学数据科学数据科学
背景情况:
- 工业设备的维护对于生产的稳定性至关重要.
- 电力行业的设备故障会造成重大经济损失.
- 采用各种维护策略,从传统到基于人工智能的维护策略.
研究的目的:
- 审查电力部门维护方法的演变.
- 分析基于IT分析的传统和现代维护技术.
- 探索工业4.0概念,如人工智能,大数据和物联网在维护.
主要方法:
- 对维护策略的文献审查.
- 对预后和健康管理 (PHM) 技术的分析.
- 在维护计划和执行中检查工业4.0技术.
主要成果:
- 记录了维护从手动到自动化和人工智能驱动的进展.
- 详细介绍了PHM技术的要求,好处和局限性.
- 识别了工业4.0技术作为高级维护的关键推动者.
结论:
- 该研究提供了对电力行业的维护实践的全面概述.
- 它弥合了现有的工程方法和新兴的人工智能驱动解决方案之间的差距.
- 提供了对流程改进和预测性维护未来研究方向的见解.
相关概念视频
Distribution Reliability and Automation
134
Distribution reliability in electrical power systems is critical for ensuring an uninterrupted power supply to consumers at minimal cost. According to IEEE Standard Terms, reliability is the probability that a device will function without failure over a specified time period or amount of usage. For electric power distribution, this translates to maintaining continuous power supply and addressing customer concerns over power outages. Several indices, as defined by IEEE Standard 1366-2012, are...
134
Control of Power Flow
292
There are several methods to control power flow in power systems:
292
Load-frequency control
197
Load-frequency control (LFC) is vital for maintaining power system stability, ensuring that frequency and power flows remain within acceptable limits during load changes. Turbine-governor control eliminates rotor accelerations and decelerations following load changes. However, a steady-state frequency error persists when the change in the turbine-governor reference setting is zero. In an interconnected power system, each area agrees to export or import a scheduled amount of power through...
197
Power Factor Correction
211
The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
211
Reclosers and Fuses
132
Automatic circuit reclosers enhance the protection of distribution circuits by interrupting and auto-reclosing an AC circuit according to a preset sequence. They effectively manage temporary faults on overhead distribution lines, often caused by tree limbs or wildlife, by briefly disrupting service to improve overall reliability. However, contact with reclosers or energized broken conductors on the ground can pose serious hazards.
A comprehensive protection scheme for radial distribution...
A comprehensive protection scheme for radial distribution...
132
Power System Three-Phase Short Circuits
114
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
114