离子交换过程参数对宽带差异干扰的影响
1Department of Optoelectronics, Silesian University of Technology, 2 Krzywoustego Str., 44-100 Gliwice, Poland.
Sensors (Basel, Switzerland)
|July 14, 2023
概括
本研究探讨了离子交换玻璃波导中的宽带差异干扰,这些波导对于生物系统中敏感的折射率测量非常理想.
科学领域:
- 光学和光子学 在光学和光子学.
- 材料科学 材料科学 材料科学
- 传感器技术 传感器技术
背景情况:
- 在BK-7玻璃中通过K+-Na+离子交换制造的平面梯度波导显示出显著的极度分散.
- 这一特性使得它们适用于先进的干扰度应用.
研究的目的:
- 理论分析和实验研究这些波导中的宽带差异干扰.
- 了解技术参数如何影响传感器性能.
- 探索在需要精确折射率传感的生物系统中的应用.
主要方法:
- 在平面梯度波导中差异干扰的理论建模.
- 在BK-7玻璃中使用K+-Na+离子交换的波导的实验制造.
- 波导性能的表征,包括极度分散和光谱输出.
主要成果:
- 证明了宽带差异干扰能力.
- 确定了技术参数和传感器特征之间的关系.
- 展示了外部折射率变化对模态特性 (TE/TM模式) 和光谱输出的影响.
结论:
- 交换K+-Na+离子的BK-7玻璃波导对差异干扰测量非常有效.
- 该技术非常适合生物传感应用,因为它对折射率变化的灵敏度很高.
相关概念视频
Ion-Exchange Chromatography
594
Ion-exchange chromatography, or IEC, is a technique for separating ions based on their affinity for the stationary phase. The stationary phase is a cross-linked polymer resin with covalently attached ionic functional groups. The functional groups can be either positively charged (cation exchangers) or negatively charged (anion exchangers). A cation exchanger consists of a polymeric anion and active cations, while an anion exchanger is a polymeric cation with active anions. The choice of...
594
Ion Exchange
624
Ion exchange chromatography separates charged molecules from a solution by reversibly exchanging them with mobile, or 'active', ions associated with the oppositely charged stationary phase. This method can be used to separate ions, soften and deionize water, and purify solutions. The polymers comprising the ion-exchange column are high-molecular-weight and chemically stable polymers, crosslinked to be porous and essentially insoluble. They are also functionalized with either acidic or...
624
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
524
Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and...
524
Dialysis
734
Dialysis is a diffusion-based purification process that separates analyte molecules from a complex matrix. This is accomplished by allowing molecules in the solution to pass through a semipermeable membrane into a liquid on the other side. The membrane is usually made of cellulose acetate or cellulose nitrate, and the second liquid must be miscible with the solution. Ions (e.g., chloride or sodium) or organic molecules (e.g., glucose) can pass through the membrane pores, which generally have...
734
Interference: Path Lengths
1.3K
Consider two sources of sound, that may or may not be in phase, emitting waves at a single frequency, and consider the frequencies to be the same.
Two special sources may be considered when they are in phase. This can be easily achieved by feeding the two sources from the same source. An example would be synchronizing the two speakers by feeding them with the same source, such as the sound waves produced by a tuning fork. This setup ensures that the two sources have the same frequency and are...
Two special sources may be considered when they are in phase. This can be easily achieved by feeding the two sources from the same source. An example would be synchronizing the two speakers by feeding them with the same source, such as the sound waves produced by a tuning fork. This setup ensures that the two sources have the same frequency and are...
1.3K
Atomic Absorption Spectroscopy: Interference
849
Interference leads to systematic error in atomic absorption (AA) measurements by enhancing or diminishing the analytical signal or the background. These interferences can be grouped into three main categories: spectral interference, chemical interference, and physical interference.
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
849


