通过360度旋转平台模拟微重力视角,在各种倾斜处对人类心脏脉冲参数的响应
Sagar Jagtap1, Ajay Kumar2,3, Bhoopesh Mahale4
1Department of Physics, Haribhai V. Desai College, Pune, MS, 411002, India. ssjagtap83@gmail.com.
NPJ microgravity
|July 18, 2023
概括
宇航员在太空中经历心血管变化. 一个新的360度旋转平台模拟微重力,揭示可逆心脏适应,并建议270度的头向下倾斜作为研究宇航员心脏反应的优越模拟.
科学领域:
- 心血管生理学心血管生理学
- 太空医学 太空医学
- 生物医学工程 生物医学工程
背景情况:
- 人的心血管系统适应了地球的重力.
- 在太空飞行期间暴露于微重力显著改变心血管功能.
- 像头向下倾斜 (HDT) 这样的地面类型用于研究这些效应,但存在局限性.
研究的目的:
- 为了研究心血管参数反应和循环适应,使用一个新的360度旋转平台.
- 为了评估不同倾斜的有效性作为微重力类型.
- 将观察到的心脏反应与已知的太空飞行效应进行比较.
主要方法:
- 18名健康的男性受试者使用本土开发的360度旋转平台进行了研究.
- 心脏脉冲被记录在30°的倾斜间隔从0°到360°使用压电脉冲传感器.
- 分析了相关的心脏参数,以评估循环适应.
主要成果:
- 在旋转过程中观察到脉冲形状和心脏参数振荡模式的显著变化.
- 心脏反应在返回卧卧姿势后正常化,表明可逆适应.
- 在270°倾斜时心脏参数的变化与太空飞行观测结果相当.
结论:
- 360度旋转平台有效模拟微重力对心血管系统的影响.
- 270°的头向下倾斜倾斜显示出作为微重力模拟器的特别前景.
- 这种方法可以提高对宇航员心脏反应的理解,特别是在短期任务中.
相关概念视频
Variation in Acceleration due to Gravity near the Earth's Surface
2.4K
An object's apparent weight is its weight measured by a spring balance at its location. It is different from its true weight, the force with which the Earth pulls it, because of the Earth's rotation. Mathematically, an object's apparent weight equals its true weight minus the centripetal force that keeps it in a circular motion along with the Earth's surface every 24 hours.
The difference between the true and apparent weights is proportional to the square of the Earth's...
The difference between the true and apparent weights is proportional to the square of the Earth's...
2.4K
Assessment of apical radial pulse
788
Apical-Radial (A-R) Pulse Assessment
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
788
Measuring Acceleration Due to Gravity
596
Consider a coffee mug hanging on a hook in a pantry. If the mug gets knocked, it oscillates back and forth like a pendulum until the oscillations die out.
A simple pendulum can be described as a point mass and a string. Meanwhile, a physical pendulum is any object whose oscillations are similar to a simple pendulum, but cannot be modeled as a point mass on a string because its mass is distributed over a larger area. The behavior of a physical pendulum can be modeled using the principles of...
A simple pendulum can be described as a point mass and a string. Meanwhile, a physical pendulum is any object whose oscillations are similar to a simple pendulum, but cannot be modeled as a point mass on a string because its mass is distributed over a larger area. The behavior of a physical pendulum can be modeled using the principles of...
596
Assessment of radial pulse
876
Assessment of Radial Pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
876
Special considerations while measuring pulse
617
Assessing a patient's pulse is a fundamental skill in healthcare, but certain situations require special attention:
617
Pulse rhythm
842
Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
842