线性极化红外光谱仪用于分析生物材料
Callum Gassner1, Jitraporn Vongsvivut2, Soon Hock Ng3
1Centre for Biospectroscopy, School of Chemistry, Monash University, Clayton, Australia.
Applied spectroscopy
|July 19, 2023
概括
极化红外光谱 (p-IR) 正在从基础研究向诊断疾病的现实应用发展. 本综述详细介绍了p-IR分析生物分子,细胞和组织的方法,强调了其诊断潜力.
科学领域:
- 生物物理学的生物物理.
- 频谱学是一种光谱学.
- 生物分子分析.
背景情况:
- 极化红外光谱 (p-IR) 传统上用于确定样品的方向和结构.
- 最近的研究转移了重点,从基本化学到病理状态评估的临床应用.
研究的目的:
- 提供对使用线性极化红外光谱 (p-IR) 分析的生物材料的最新知识审查.
- 讨论p-IR在生物环境中的理论,方法,样品制备,特性,仪器和应用.
主要方法:
- 对线性极化红外光谱 (p-IR) 在生物分子,细胞和组织上的应用进行了审查.
- 讨论理论方面,不同的p-IR模式及其局限性.
- 分析影响p-IR结果的因素,包括样本准备和仪器仪表.
主要成果:
- p-IR提供了对生物样本结构和方向的洞察.
- 新兴的极化光源,如同步子光和量子级联激光器,提供了新的可能性.
- 该方法越来越多地用于病理状态评估.
结论:
- p-IR是生物样本结构和定向分析的宝贵工具.
- 该技术显示出临床诊断的巨大潜力.
- 未来的方向包括仪器仪表的进步和与其他技术的整合,以提高临床效用.
相关概念视频
Infrared (IR) Spectroscopy: Overview
1.9K
When electromagnetic radiation passes through a material, atoms or molecules transition from a lower to a higher energy state by absorbing radiation corresponding to the energy difference between the two states. The absorption of infrared (IR) radiation causes transitions between vibrational energy levels in a molecule. Therefore, IR spectroscopy is a useful analytical tool for determining the molecular structure of molecules.
Different compounds display unique properties due to their...
Different compounds display unique properties due to their...
1.9K
Applications of IR Spectroscopy: Overview
788
The non-destructive nature and ability to provide valuable chemical information make IR spectroscopy a versatile technique with broad applications in various scientific and industrial fields. IR spectroscopy is commonly used to identify and characterize organic and inorganic compounds. It provides information about the functional groups present in a molecule and the bonding between atoms. This helps in the structural elucidation of compounds during organic synthesis, pharmaceutical research,...
788
IR Spectrometers
1.2K
There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
1.2K
IR Spectrum
1.1K
When infrared (IR) radiation passes through a molecule, the bonds stretch or bend by absorbing the radiation. This absorption creates the molecule's absorption spectrum, which is the plot of its percentage transmittance versus wavenumber.
Transmittance is defined as the ratio of the radiant power passing through a sample to that from the radiation's source. Multiplying the transmittance by 100 gives the percent transmittance (%T), which varies between 100% (no absorption) and 0%...
Transmittance is defined as the ratio of the radiant power passing through a sample to that from the radiation's source. Multiplying the transmittance by 100 gives the percent transmittance (%T), which varies between 100% (no absorption) and 0%...
1.1K
IR Spectroscopy: Molecular Vibration Overview
2.5K
When Infrared (IR) radiation passes through a covalently bonded molecule, the bonds transition from lower to higher vibrational levels. The fundamental vibrational motions that result in infrared absorption can be classified as stretching or bending vibrations.
Stretching vibrations are vibrational motions that occur along the bond line, changing the bond length or distance between two bonded atoms. They are further distinguished as symmetric or asymmetric. In symmetric stretching, the...
Stretching vibrations are vibrational motions that occur along the bond line, changing the bond length or distance between two bonded atoms. They are further distinguished as symmetric or asymmetric. In symmetric stretching, the...
2.5K
IR Frequency Region: Fingerprint Region
944
IR spectra are divided into two main regions: the diagnostic region and the fingerprint region. The diagnostic region of the spectrum lies above 1500 cm−1. The absorptions resulting from single-bond vibrations of the N–H, C–H, and O–H stretch at higher wavenumbers and appear on the left side of the spectrum. The stretching absorptions of the C≡C and C≡N occur between 2100–2300 cm−1. In contrast, those arising from stretching absorptions of the...
944