用于在人体皮肤体内生物力学表征的设备的定量比较
Håvar J Junker1, Bettina Thumm1, Sascha Halvachizadeh2
1Present address: Institute for Mechanical Systems, Department of Mechanical and Process Engineering, ETH Zurich, Leonhardstrasse 21, Zurich, 8092 Switzerland.
Mechanics of soft materials
|July 19, 2023
概括
这项研究比较了三种非侵入性皮肤表征装置:吸收,动态剪切和缩. 结果显示,这些方法以不同的方式测量皮肤硬性,影响临床研究的解释.
科学领域:
- 生物医学工程 生物医学工程
- 皮肤病学 皮肤病学
- 材料科学 材料科学 材料科学
背景情况:
- 非侵入性皮肤表征对于临床研究至关重要.
- 有许多技术可以测量皮肤的生物力学特性.
- 缺乏对常见方法的比较分析.
研究的目的:
- 描述和比较三种常见的皮肤生物力学测试原理:吸收,动态剪切负荷和缩.
- 评估它们在体内分辨皮肤特性的能力.
- 评估每个设备的可靠性.
主要方法:
- 使用了具有可调整机械性能的合成模型系统.
- 采用有限元模型进行结果合理化.
- 在身体不同部位的健康志愿者身上进行了体内测量.
主要成果:
- 三个分析的功能原理不同地感知人类皮肤的性.
- 在体内测量表明在皮肤生物力学差异化方面具有不同的能力.
- 在设备中,评价器内和评价器间的可靠性各不相同.
结论:
- 选择非侵入性皮肤表征装置会影响测量结果.
- 了解这些差异对于准确解释皮肤生物力学数据至关重要.
- 需要进一步的研究来标准化临床皮肤研究的方法.
相关概念视频
Equipments Used to Measure Body Temperature
Body temperature can be assessed using various devices and measured in Celsius or Fahrenheit.
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Equipments Used To Measure Blood Pressure
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Electronic Distance Measuring Instruments
Electronic Distance Measuring Instruments (EDMs) are essential tools in modern surveying, offering precise distance measurements by emitting electromagnetic signals and calculating the time required for these signals to travel to a target and return. Two primary types of signals are used in EDMs — light waves and microwaves — each suited to specific environmental and distance requirements. Light-wave-based EDMs utilize either infrared or laser light, providing high accuracy over short distances...
Measurement of Fluid Pressure
Fluid pressure is commonly measured using devices called manometers, which rely on liquid columns to indicate pressure differences. The height of a liquid column in a manometer reflects the pressure exerted by the fluid, providing a simple yet effective means of measurement. Different types of manometers serve specific purposes based on their configurations and the type of fluids involved.
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...