心率处理算法和运动持续时间对两肌穿戴的Polar Verity Sense和OH1可穿戴设备的可靠性和有效性决定
James W Navalta1, Dustin W Davis2, Elias M Malek2
1Department of Kinesiology and Nutrition Sciences, University of Nevada, Las Vegas, Las Vegas, NV, USA. james.navalta@unlv.edu.
Scientific reports
|July 20, 2023
概括
消费者可穿戴的心率监测器在步道跑步时显示出不同的精度. 极地真实感表现出可靠和有效的结果,而OH1在特定测量方面存在一些局限性.
科学领域:
- 运动生理学 运动生理学
- 生物医学工程 生物医学工程
- 可穿戴技术可穿戴技术
背景情况:
- 消费者可穿戴技术的广泛采用需要验证在现实世界条件下收集的数据.
- 缺乏处理运动心率数据的标准化协议,使得对可穿戴设备准确性的解释变得复杂.
- 评估可靠性和有效性对于在体育活动期间信任消费者可穿戴设备的数据至关重要.
研究的目的:
- 确定不同数据处理方法对消费者可穿戴设备心率数据的可靠性和有效性的影响.
- 通过使用已确定的统计指标,比较Polar Verity Sense和OH1设备在轨道运行中的性能.
- 提供关于可穿戴心率计在不受控制的运动环境中的准确性的见解.
主要方法:
- 在步道跑步期间,从极地垂直感和OH1评估心率数据.
- 使用变化系数 (CV) 和类内相关系数 (ICC) 评估可靠性.
- 通过平均绝对百分比误差 (MAPE) 和林的一致性相关系数 (CCC) 确定有效性.
主要成果:
- 极地真实感始终满足可靠性 (CV < 5%,ICC > 0.7) 和有效性 (MAPE < 5%,CCC > 0.9) 的门.
- OH1满足了可靠性值,除了整个会话的平均值 (ICC = 0.57) 和有效性MAPE值 (3.3-4.1%),但没有CCC (0.6-0.86).
- 如果收集了足够的数据点,数据处理方法可能不会显著影响可靠性和有效性;大量的数据可能会膨胀指标.
结论:
- 极地真实感应在步道运行期间对心率监测具有很高的可靠性和有效性.
- OH1显示了特定可靠性和有效性指标的潜在局限性,特别是在总体会话准确性和一致性方面.
- 在现实环境中验证可穿戴心率数据是必不可少的,设备特定的性能有所不同.
相关概念视频
Factors Influencing Heart Rate
2.9K
The heart rate, or pulse rate, is a vital indicator of cardiovascular health. It reflects the number of times the heart beats per minute. Various physiological and environmental factors influence heart rate, increasing or decreasing cardiac output. Understanding these factors is crucial for assessing heart function and identifying potential health issues.
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
2.9K
Special considerations while measuring pulse
617
Assessing a patient's pulse is a fundamental skill in healthcare, but certain situations require special attention:
617
Pulse rhythm
842
Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
842
Holter Monitor: 24-Hour Monitoring
59
Holter monitoring is a continuous electrocardiography (ECG) recording that tracks the heart's electrical activity over an extended period, generally 24 to 48 hours. This noninvasive diagnostic tool detects irregular heart rhythms that may not be captured during a standard ECG performed in a clinical setting.DeviceThe Holter monitor is a portable, small device connected to several electrodes on the patient's chest. These electrodes detect the heart's electrical signals and transmit them to the...
59
Correlation between ECG and Cardiac Cycle
7.1K
The electrical signals recorded on an electrocardiogram (ECG) occur before the mechanical processes of contraction and relaxation during the cardiac cycle.
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
7.1K
Electrocardiogram
2.5K
An electrocardiogram (ECG or EKG) is a critical diagnostic tool that records the electrical signals produced by the heart during each heartbeat. This recording is achieved through electrodes placed strategically on the arms, legs, and chest. The electrocardiograph amplifies these signals and produces 12 distinct tracings, offering a comprehensive understanding of the heart's electrical activity.
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
2.5K