瑞典与电网连接的分散式屋顶光伏系统在瑞典的潜力
Tianqi Ruan1, Monika Topel1, Wujun Wang1
1Department of Energy Technology, KTH Royal Institute of Technology, Brinellvägen 68, Stockholm, 11428, Sweden.
Heliyon
|July 24, 2023
概括
分散的太阳能光伏 (PV) 系统在瑞典城市中显示出相当大的电力潜力,提供了一个有前途的可再生能源选择,而无需土地使用. 完善的基础设施和有利的市场条件是最大限度地帮助实现2040年可再生能源目标的关键.
科学领域:
- 可再生能源系统可再生能源系统
- 可持续的发电是可持续的发电.
- 城市规划 城市规划
背景情况:
- 瑞典目前的太阳能发电容量不足以实现2040年的可再生能源转型.
- 能源需求的增加和城市土地稀缺凸显了对分散解决方案的需求.
- 实施分散的光伏 (PV) 系统面临着由于当地条件和有限的案例研究而面临的挑战.
研究的目的:
- 提供瑞典小型电网光伏系统潜力的概述.
- 为高度地区的城市光伏系统规划提供一个模型和案例研究.
- 评估瑞典分散式屋顶光伏技术的技术和经济可行性.
主要方法:
- 开发一个综合模型,整合天气,空间,基础设施和经济因素.
- 采用瑞典背景下的现实世界案例研究来实施该模型.
- 分析电力潜力,土地需求和系统可行性.
主要成果:
- 在瑞典,城市分散式屋顶光伏系统在技术和经济上是可行的.
- 这些系统具有相当大的发电潜力,不需要额外的土地.
- 光伏系统可以部分满足能源需求,减轻国家电网的压力.
结论:
- 分散的屋顶光伏是瑞典城市未来发电的可行选择.
- 充分发挥潜力需要基础设施改进和有利的市场/政治条件.
- 这项研究可以作为类似的高度地区的宝贵参考.
更多相关视频
09:19In Situ Monitoring of the Accelerated Performance Degradation of Solar Cells and Modules: A Case Study for CuIn,GaSe2 Solar Cells
Published on: October 3, 2018
8.4K
12:08Fabrication of High Contrast Gratings for the Spectrum Splitting Dispersive Element in a Concentrated Photovoltaic System
Published on: July 18, 2015
10.8K
相关概念视频
Secondary Distribution
108
Secondary distribution systems provide electrical energy at the utilization voltage levels from distribution transformers to customer meters. Typical secondary voltages in the United States include 120/240 V for residential use, 208Y/120 V for residential and commercial use, and 480Y/277 V for industrial and high-rise commercial use.
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
108
P-N junction
583
A p-n junction is formed when p-type and n-type semiconductor materials are joined together. At the interface of the p-n junction, holes from the p-side and electrons from the n-side begin to diffuse into the opposite sides due to the concentration gradient. This diffusion of carriers leads to a region around the junction where there are no free charge carriers, known as the depletion region. The charge density within the depletion region for the n-side and p-side can be described by the...
583
Primary Distribution
126
Primary distribution systems deliver electrical power from substations to consumers through various voltage classes, with 15-kV class voltages being predominant among U.S. utilities. Older 2.5- and 5-kV classes are being replaced by 15-kV primaries, while higher 25- to 34.5-kV classes are used in high-density urban areas and rural regions with long feeders. Three-phase, four-wire multigrounded systems are widely employed for balanced power delivery, using the neutral wire as a grounding point.
126
Maximum Power Flow and Line Loadability
138
The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
138
Generation of Three-Phase Voltage
416
A three-phase AC generator has a rotor with a rotating magnet placed within the stator mounted with the stationary three-phase winding to generate three-phase voltages via mutual induction. These windings are evenly distributed around the inner circumference of the stator and are arranged 120 electrical degrees apart. Three-phase stator windings consist of three separate coils or groups of coils, known as phases, each connected in Y (star) configuration or Delta configuration.
As the rotor...
As the rotor...
416
Power System Distribution
268
Power system distribution involves delivering electrical energy from power plants to consumers through a network of transmission and distribution systems. The process begins at power plants, where energy from coal, gas, nuclear, water, and wind is converted into electrical energy. These plants use three-phase generators, typically rated between 50 to 1300 MVA, with terminal voltages ranging from a few kV to 20 kV, depending on the size and age of the units.
The transmission system is designed...
The transmission system is designed...
268