对比介质对使用双能CT检测的对比介质的影响:幻影研究和临床说明
Maximilian Kotlyarov1, Jürgen Mews2, Sevtap Tugce Ulas3
1Department of Radiology, Charité - Universitätsmedizin Berlin, Campus Mitte, Humboldt-Universität Zu Berlin, Freie Universität Berlin, 10117, Berlin, Germany. maximilian.kotlyarov@charite.de.
European radiology experimental
|July 24, 2023
概括
含的对比剂 (ICM) 可以在低度的双能量CT扫描中改善单酸盐 (MSU) 晶体的检测. 然而,高ICM度显著阻碍了MSU的检测,可能会掩盖痛风.
科学领域:
- 放射学 放射学是指放射学
- 医疗成像医学成像
- 痛风的诊断 痛风的诊断
背景情况:
- 双能计算断层扫描 (DECT) 用于检测甲酸盐 (MSU) 晶体沉积在痛风中.
- 化对比剂 (ICM) 对使用DECT检测MSU的影响需要澄清.
研究的目的:
- 研究ICM如何影响DECT的MSU检测.
- 评估不同ICM度对MSU检测在幻影研究中的影响.
- 用一个病例来说明临床相关性.
主要方法:
- 使用DECT扫描了两种类型的幻影 (网状和生物幻影),MSU和ICM度各不相同.
- 管道电流在不同的kVp设置中进行调整.
- 使用临床痛风软件量化MSU检测,用于体积和质量测量.
主要成果:
- 较低的ICM度 (0.25-0.50%) 提高了MSU晶体的检测.
- 较高的ICM度 (1-2%) 在所有度中显著损害了MSU检测.
- 在临床案例中,只有在静脉注射ICM后才可视化手腕托菲.
结论:
- 通过DECT,ICM可以帮助可视化以前未被检测到的MSU沉积物.
- 最佳ICM度至关重要,因为过度增强可以掩盖痛风.
- 多模式DECT策略可以改善关节炎成像和托菲斯检测.
相关概念视频
Radiological Investigation I: X-ray and CT
290
Radiological investigations, including X-rays and computed tomography (CT) scans, are critical for diagnosing and evaluating various medical conditions. These imaging techniques provide valuable insights into the body's internal structures, aiding in the detection of abnormalities, assessment of disease progression, and development of treatment strategies. This article delves into two primary radiological investigations, chest X-rays and CT scans, outlining their purpose, procedures, and...
290
Computed Tomography
4.6K
Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
4.6K
Imaging Studies for Cardiovascular System V: CT
42
Cardiac computed tomography (CT) scanning is an advanced cardiac imaging technique that utilizes CT technology, with or without intravenous (IV) contrast, to produce accurate cross-sectional virtual slices of specific areas of the heart, coronary circulation, and major blood vessels such as the aorta, pulmonary veins, and arteries. The computer processes these slices to generate three-dimensional images. Multidetector CT (MDCT) is a rapid form of CT scanning that captures multiple slices...
42
Ultrasonography
4.6K
Ultrasonography is an imaging technique that uses high-frequency sound waves to visualize the body's internal structures. It is a non-invasive and safe procedure that does not involve the use of ionizing radiation, making it widely used in various medical fields. Ultrasonography is used to study heart function, blood flow in the neck or extremities, certain conditions such as gallbladder disease, and fetal growth and development.
During an ultrasonography procedure, a handheld device called...
During an ultrasonography procedure, a handheld device called...
4.6K
X-ray Imaging
5.6K
German physicist Wilhelm Röntgen (1845–1923) was experimenting with electrical current when he discovered that a mysterious and invisible "ray" would pass through his flesh but leave an outline of his bones on a screen coated with a metal compound. In 1895, Röntgen made the first durable record of the internal parts of a living human: an "X-ray" image (as it came to be called) of his wife’s hand. Scientists worldwide quickly began their own experiments with...
5.6K
Effects of EDTA on End-Point Detection Methods
306
Different methods, such as visual observance of metal-ion indicators, spectroscopic techniques, and potentiometric methods, can determine the endpoint of an EDTA titration.
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
306