针对血液透析护士的麦金泰尔审计工具的可行性
David McIntyre1,2, Amanda McGuire1, Ann Bonner1,3
1School of Nursing and Midwifery & Menzies Health Institute Queensland, Griffith University, Brisbane, QLD, Australia.
Journal of renal care
|July 26, 2023
概括
麦金泰尔审计工具 (MAT) 是一种可行且可接受的方法,用于审计血液透析单位的护理质量. 这种工具可以帮助通过基准测试建立标准并改善患者护理.
科学领域:
- 提高护理质量 提高护理质量
- 医疗保健审计 医疗保健审计
- 脏护理实践中的护理实践
背景情况:
- 护士敏感指标 (NSI) 评估患者护理的质量,包括结构,流程和结果.
- 麦金泰尔审计工具 (MAT) 专门设计用于在血液透析设置中测量NSI.
研究的目的:
- 评估麦金泰尔审计工具 (MAT) 的可行性和实用性,用于在现实临床环境中测量血液透析护士敏感指标.
- 确定使用MAT用于血液透析单元质量评估的可行性和接受性.
主要方法:
- 进行了一项多站点的非随机可行性研究.
- 来自澳大利亚两家血液透析病房的30名护士参加了这次活动.
- 护士每天完成一周的MAT,同时收集可行性和实用性数据. 使用了描述性分析.
主要成果:
- 大多数结构性 (75%) 和过程性 (73%) 指标都得到了满足,但在各站点之间存在一些差异.
- 结果指标显示出更大的变化,从5.9%到94.1%不等.
- 发现MAT是可行的,大多数护士在5分钟内完成它,认为它易于使用和可以在一个班次内实施.
结论:
- 麦金泰尔审计工具 (MAT) 是一个实用且被广泛接受的工具,用于审计血液透析护理的护理质量.
- 实施MAT可以促进建立最低护理标准,提高护理实践的质量.
- 该工具支持对不同血液透析服务的护理质量进行基准评估.
相关概念视频
Hemodialysis III: Nursing Management
50
The nursing management of a patient undergoing hemodialysis includes several critical steps, starting with a thorough assessment before the procedure.Before the Hemodialysis ProcedureFirst, record the patient's vital signs—blood pressure, heart rate, respiratory rate, and temperature—to establish a baseline. This baseline is essential for detecting conditions such as hypotension that could impact the patient's response to dialysis. Document the patient's pre-dialysis weight, as this...
50
Peritoneal Dialysis III: Nursing Management
47
Peritoneal dialysis, or PD, utilizes the peritoneal membrane as a filter to eliminate excess fluid and waste products. Effective nursing management is essential for ensuring patient safety, preventing complications, and promoting optimal function of the peritoneal dialysis process.Assessment and MonitoringNurses must thoroughly assess the patient before, during, and after each dialysis session. Regular monitoring includes vital signs, daily weight, fluid intake and output, and laboratory values...
47
Chronic Kidney Disease IV: Nursing Management
25
Nursing management is essential for preventing complications, maintaining stability, and improving patients' quality of life in chronic kidney disease (CKD). By using a structured approach, nurses help slow CKD progression and support effective patient care.1. Comprehensive patient assessmentEffective management begins with nurses reviewing the patient’s medical history, and identifying key risk factors like diabetes, hypertension, and nephrotoxic drug use. Nurses assess signs of...
25
Hemodialysis II: Procedure and Complications
42
DialyzersA hemodialysis (HD) dialyzer is a plastic cartridge containing thousands of parallel hollow fibers, which serve as semipermeable membranes. These fibers are typically made from cellulose-based or other synthetic materials. During HD, blood is pumped into the top of the cartridge and distributed among these fibers. Simultaneously, dialysis fluid, known as dialysate, is introduced into the bottom of the cartridge, bathing the outside of the fibers. Across the semipermeable membrane,...
42
Hemodialysis I: Introduction
57
Hemodialysis (HD) is a medical treatment that artificially removes waste products, excess fluids, and toxins from the blood when the kidneys are no longer able to perform these functions effectively. In this process, blood is filtered through a semipermeable membrane, allowing for the selective removal of waste while preserving necessary components like blood cells and proteins. Hemodialysis is typically performed in patients with end-stage renal disease (ESRD) or severe kidney...
57
Acute Kidney Injury V: Interprofessional Care
26
Acute Kidney Injury (AKI) requires a collaborative healthcare approach to restore renal function and prevent complications. Essential management strategies involve monitoring fluid and electrolyte balance, adjusting medications, initiating dialysis when necessary, and providing nutritional support.Fluid and Electrolyte ManagementFluid Monitoring: Regularly monitoring body weight, central venous pressure, and urine output helps detect fluid imbalances early. Patient intake and output are...
26