非离子离子对比介质的稀释放大和辐射剂量的放大效应之间的关系
Kuniharu Imai1, Kento Takeda1, Keisuke Fujii1
1Department of Integrated Health Sciences, Nagoya University Graduate School of Medicine, Nagoya, Aichi, Japan.
Journal of neuroendovascular therapy
|July 28, 2023
概括
用水稀释含的对比剂,在神经内血管程序中增加了辐射剂量放大. 增加对比介质在脑血管中的扩散,而不仅仅是内容,驱动了这种辐射剂量效应.
科学领域:
- 放射学 放射学是一门学科.
- 医学物理 医学物理
- 神经内血管干预 神经内血管干预
背景情况:
- 神经内血管治疗为外科切割提供了一个不那么侵入性的替代方案.
- 增加光镜运行和对比剂在这些程序中的使用可以提高辐射剂量.
- 了解放大辐射剂量的因素对于患者安全至关重要.
研究的目的:
- 研究如何用水稀释含的对比介质影响辐射剂量放大.
- 确定在神经内血管程序中促进辐射剂量放大的物理因素.
主要方法:
- 使用数值大脑幻影进行模拟分析.
- 蒙特卡洛法用于估计在X射线暴露下吸收的能量.
- 药物动力学和碎形分析以预测对比介质的含量和体积.
主要成果:
- 吸收能量增加与对比介质的二次电子有关.
- 辐射剂量放大随着对比介质的更大稀释而增加.
- 放大效果因使用的对比介质类型而异.
结论:
- 辐射剂量放大与X射线相互作用的横截面积增加有关,这是由于对比介质的分布.
- 对比介质在脑血管中的分布比含量更为关键,因为在稀释时剂量放大.
- 稀释策略需要仔细考虑,以管理神经内血管干预期间的辐射暴露.
相关概念视频
Radiological Investigation I: X-ray and CT
290
Radiological investigations, including X-rays and computed tomography (CT) scans, are critical for diagnosing and evaluating various medical conditions. These imaging techniques provide valuable insights into the body's internal structures, aiding in the detection of abnormalities, assessment of disease progression, and development of treatment strategies. This article delves into two primary radiological investigations, chest X-rays and CT scans, outlining their purpose, procedures, and...
290
Dose-Response Relationship: Overview
3.2K
Agonists can bind with and activate receptors, resulting in the formation of drug-receptor complexes. Once formed, these complexes catalyze many biochemical processes at the cellular level and subsequently induce a pharmacologic response. The degree of response is directly proportional to the fraction of activated receptors, which in turn, depends on the concentration of the drug at the receptor site as well as the sensitivity of the receptor. An increase in the administered dose contributes to...
3.2K
Nuclear Overhauser Enhancement (NOE)
742
Irradiation of a spin-active nucleus causes an increase or decrease in the signal intensity of neighboring nuclei that are not necessarily chemically bonded or involved in J-coupling. This phenomenon, called the Nuclear Overhauser Enhancement (NOE), results from through-space interactions between the nuclear spins. The NOE effect decreases with increasing internuclear distance and is generally not observed beyond 4 angstroms. In NOE, dipole-dipole interactions between neighboring...
742
Biological Effects of Radiation
15.5K
All radioactive nuclides emit high-energy particles or electromagnetic waves. When this radiation encounters living cells, it can cause heating, break chemical bonds, or ionize molecules. The most serious biological damage results when these radioactive emissions fragment or ionize molecules. For example, α and β particles emitted from nuclear decay reactions possess much higher energies than ordinary chemical bond energies. When these particles strike and penetrate matter, they...
15.5K
Imaging Studies III: Computed Tomography
28
DefinitionComputed Tomography (CT) of the genitourinary (GU) tract is a non-invasive imaging modality that utilizes X-rays and computer processing to generate detailed cross-sectional images of the urinary system, encompassing the kidneys, ureters, bladder, and adjacent structures such as the adrenal glands.PurposeCT scans of the GU tract serve several diagnostic and therapeutic purposes, including:Diagnosis of Urinary Tract Diseases: Detects kidney stones, tumors, cysts, and congenital...
28
Solution Concentration and Dilution
84.6K
The relative amount of a given solution component is known as its concentration. Often, though not always, a solution contains one component with a concentration that is significantly greater than that of all other components. This component is called the solvent and may be viewed as the medium in which the other components are dispersed or dissolved. Solutions in which water is the solvent are, of course, very common on our planet. A solution in which water is the solvent is called an aqueous...
84.6K