光素pH探针在水性介质中的运行:温度和粘度的影响
Darya P Surzhikova1, Lev A Sukovatyi2, Elena V Nemtseva2,3
1Institute of Engineering Physics and Radioelectronics, Siberian Federal University, 660041 Krasnoyarsk, Russia.
Micromachines
|July 29, 2023
概括
粘性剂如糖醇和糖糖会影响光素.
科学领域:
- 分析化学 分析化学
- 物理化学 物理化学
- 生物物理化学 生物物理化学
背景情况:
- 光素的光谱特性对其局部环境敏感.
- 了解原溶性平衡对于化学和生物传感至关重要.
- 粘性原剂可以改变溶剂特性并影响分子相互作用.
研究的目的:
- 为了研究糖醇和糖糖对光素光效应的影响.
- 为了将光素光谱信号的变化与当地的环境粘度相关联.
- 阐明溶剂粘度和温度对光素酸平衡的作用.
主要方法:
- 用光谱法测量光素的光强度.
- 添加了致粘性剂 (糖醇,糖糖) 来改变溶剂粘度.
- 进行了分子动力学模拟,以研究染料-溶剂相互作用.
- 进行了温度依赖的光测量.
主要成果:
- 甘油将光素的比值信号 (I488/I435) 增加了高达19%,而糖糖的影响最小.
- 辅溶剂优先与光素离子相互作用,减少水媒介的键.
- 分度信号显示,温度 (10-80°C) 随着温度的线性增加,不论粘度如何.
- 在温度灵敏度和质子解离的度之间发现了相关性.
结论:
- 光素的原溶解平衡受溶剂粘度的复杂影响.
- 甘油的作用归因于与染料离子的特定相互作用,改变了当地的水化.
- 光素信号的温度敏感性与其酸反应的热力学有关.
相关概念视频
Variables Affecting Phosphorescence and Fluorescence
534
Fluorescence and phosphorescence are essential phenomena in fields like analytical chemistry, biological imaging, and materials science, where they detect molecular properties and visualize cellular structures. Understanding the variables that influence these luminescent behaviors is crucial for maximizing accuracy and efficiency in their applications. These variables can broadly be grouped into chemical structure, solvent properties, and external conditions, each playing a distinct role in...
534
Fluorescence and Phosphorescence: Instrumentation
648
Fluorometers and spectrofluorometers are two types of instruments used for measuring molecular fluorescence. These instruments differ in how they select excitation and emission wavelengths and the type of light sources they utilize. Fluorometers use absorption interference filters to choose excitation and emission wavelengths. The excitation source in a fluorometer is typically a low-pressure mercury vapor lamp that emits intense lines distributed throughout the ultraviolet and visible regions.
648
Photoluminescence: Applications
433
Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...
433