在非热平衡状态下空载红外光学系统的校准方法
Mingyuan Dong1,2,3, Honghai Shen1,2, Ping Jia1,3
1Key Laboratory of Airborne Optical Imaging and Measurement, Chinese Academy of Sciences, Changchun 130033, China.
Sensors (Basel, Switzerland)
|July 29, 2023
概括
这项研究通过考虑非热平衡下的内部散射辐射来增强红外摄像机的放射性校准. 这种新方法提高了空中遥感应用的精度.
科学领域:
- 光学工程是指光学工程.
- 遥感技术 遥感技术 遥感技术
- 红外成像系统 红外成像系统
背景情况:
- 空载红外光学系统使用冷却的摄像头进行放射测量和温度测量.
- 准确的放射测量校准对于定量遥感数据至关重要.
- 传统方法假设热平衡,导致现实世界的场景中的错误.
研究的目的:
- 为在非热平衡下运行的红外系统开发改进的放射测量校准方法.
- 为了解决传统校准技术的局限性,该技术假设系统热平衡.
- 为了提高空载红外摄像机的定量测量的准确性.
主要方法:
- 分析了红外系统内的内部光学温度变化.
- 开发了一种简化的模型来解释非热平衡状态下的内部散射辐射.
- 为绝对校准程序实施了增强的放射测量校准方法.
主要成果:
- 拟议的方法实现了对中波频道的校准精度超过3.78%.
- 实验是在温度测试室内进行的,温度范围从-30°C到15°C.
- 最大温度测量误差小于±1.01°C.
结论:
- 增强的放射测量校准方法有效地弥补了非热平衡下的内部流浪辐射.
- 这种方法显著提高了空载红外系统定量放射测量和温度测量的准确性.
- 这些发现对于在不同的任务环境中可靠的数据采集至关重要.
相关概念视频
Instrument Calibration
219
Instrument calibration is essential for ensuring that instruments produce accurate and consistent results. It is vital in manufacturing, healthcare, testing laboratories, and scientific research. Calibration processes are specific to each instrument and help enhance data accuracy. Each instrument has a unique calibration process tailored to its design and function to improve data accuracy.
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
219
Infrared (IR) Spectroscopy: Overview
1.9K
When electromagnetic radiation passes through a material, atoms or molecules transition from a lower to a higher energy state by absorbing radiation corresponding to the energy difference between the two states. The absorption of infrared (IR) radiation causes transitions between vibrational energy levels in a molecule. Therefore, IR spectroscopy is a useful analytical tool for determining the molecular structure of molecules.
Different compounds display unique properties due to their...
Different compounds display unique properties due to their...
1.9K
Glassware Calibration
277
Accurate calibration of glassware, such as volumetric flasks, pipettes, and burettes, is essential to ensure accurate measurements in the analytical laboratory. Calibration helps maintain consistency across measurements and prevents errors arising from inaccurate volumes.
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
277
IR Spectrometers
1.2K
There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
1.2K
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
418
Attenuated total reflectance (ATR) infrared spectroscopy is a powerful analytical technique used to study the composition of materials. It is widely employed in chemistry, materials science, forensic science, and other fields where sample characterization is required. ATR has several advantages over traditional transmission IR spectroscopy, including the requirement of little to no sample preparation and the ability to analyze a wide range of samples.
The ATR process begins by directing a beam...
The ATR process begins by directing a beam...
418
Calibration Curves: Linear Least Squares
1.4K
A calibration curve is a plot of the instrument's response against a series of known concentrations of a substance. This curve is used to set the instrument response levels, using the substance and its concentrations as standards. Alternatively, or additionally, an equation is fitted to the calibration curve plot and subsequently used to calculate the unknown concentrations of other samples reliably.
For data that follow a straight line, the standard method for fitting is the linear...
For data that follow a straight line, the standard method for fitting is the linear...
1.4K