基于全面的电力配电网络故障检测-YOLOv5
Shengsuo Niu1, Xiaosen Zhou1, Dasen Zhou1
1Hebei Provincial Key Laboratory of Power Transmission Equipment Security Defense, North China Electric Power University, Baoding 071003, China.
Sensors (Basel, Switzerland)
|July 29, 2023
概括
本研究介绍了Comprehensive-YOLOv5,这是一种用于实时检测发电网中的缺陷的轻量级算法. 它显著提高了准确性和速度,使得边缘设备的部署更高效.
科学领域:
- 电气工程 电气工程
- 计算机视觉 计算机视觉
- 人工智能的人工智能
背景情况:
- 在配电网络中实时故障检测至关重要,但由于边缘设备的局限性而受到挑战.
- 现有的方法与边缘设备的低功耗和计算限制作斗争.
研究的目的:
- 提出一种轻量级算法,Comprehensive-YOLOv5,用于高效准确地识别发电网中的缺陷.
- 为了增强边缘设备的实时检测能力.
主要方法:
- 开发了基于YOLOv5的Comprehensive-YOLOv5,并将GhostNet纳入骨干重建.
- 综合双向特征金字塔网络 (BiFPN) 改善了特征融合.
- 使用焦点扩展交叉点在欧盟 (Focal-EIOU) 损失函数,以提高性能.
主要成果:
- 综合YOLOv5实现了90.1%的平均平均精度 (mAP),比88.3%的平均精度有所改善.
- 算法的速度增加到每秒52 (FPS),从20 FPS上升.
- 在缺陷检测中,证明了虚假阳性和虚假阴性的显著减少.
结论:
- 综合YOLOv5为发电网的实时缺陷检测提供了一个可行的解决方案.
- 该算法的轻量级设计和改进的性能使其适合于边缘部署.
- 提高检测速度和准确性提高了整体检查效率.
相关概念视频
Power System Distribution
264
Power system distribution involves delivering electrical energy from power plants to consumers through a network of transmission and distribution systems. The process begins at power plants, where energy from coal, gas, nuclear, water, and wind is converted into electrical energy. These plants use three-phase generators, typically rated between 50 to 1300 MVA, with terminal voltages ranging from a few kV to 20 kV, depending on the size and age of the units.
The transmission system is designed...
The transmission system is designed...
264
Power System Three-Phase Short Circuits
112
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
112
Power Distribution in Three-phase and Single Phase Circuits
346
Power distribution within electrical circuits is a foundational aspect of residential and industrial energy systems. While single-phase power is common in residential settings, three-phase power is the standard for industrial environments with heavy machinery. Each system is different and has advantages, and it's crucial to understand the underlying principles of power distribution and material efficiency.
Single-Phase Power Distribution:
Single-phase circuits are typical in household...
Single-Phase Power Distribution:
Single-phase circuits are typical in household...
346
Maximum Power Flow and Line Loadability
138
The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
138
Electrical Power
3.1K
Electric power is the product of current and voltage, represented in units of joules per second, or watts. For example, cars often have one or more auxiliary power outlets with which you can charge a cell phone or other electronic devices. These outlets may be rated at 20 amps and 12 volts, so that the circuit can deliver a maximum power of 240 watts. Consider a 25 Watt bulb and a 60 Watt bulb. The conversion of electrical energy produces heat and light, while the kinetic energy lost by the...
3.1K
Power Factor Correction
207
The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
207