听觉光电显微镜分析的原理和在生理监测中的应用-一篇评论
Khalida Azudin1, Kok Beng Gan1, Rosmina Jaafar1
1Department of Electrical, Electronic & Systems Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, Bangi 43600, Selangor, Malaysia.
Sensors (Basel, Switzerland)
|July 29, 2023
概括
带有光电发热学 (PPG) 的智能耳机提供可靠的生理监测. 本综述探讨了耳内PPG技术,其应用,以及未来医疗保健进步的挑战.
科学领域:
- 生物医学工程 生物医学工程
- 可穿戴技术可穿戴技术
- 生理监测 生理监测
背景情况:
- 听觉设备已经从音频设备演变为复杂的生物传感器.
- 智能耳机现在集成了生命体征监测功能.
- 耳机中的光电脉冲图 (PPG) 能够进行全面的生理数据收集.
研究的目的:
- 审查关于耳内PPG信号及其应用的现有文献.
- 为了确定当前的耳内PPG技术,使用情况和生理监测的证据.
- 分析耳内PPG测量配置,原理,波形特征,处理和特征提取.
主要方法:
- 在2022年12月之前,对耳内PPG研究进行全面的文献搜索.
- 搜索的数据库包括IEEE,ScienceDirect,Scopus,科学网络和PubMed.
- 包括专注于用于生理监测的耳内PPG的研究.
主要成果:
- 确定了14项研究,其中9项已完成审查.
- 八项研究重点关注可听的PPG原理/配置,八项研究关注处理/特征提取.
- 强调了用于生理监测的耳内PPG的局限性和挑战.
结论:
- 耳内PPG显示出未来生理监测应用的巨大潜力.
- 需要进一步的研究来解决信号处理和克服固有的挑战.
- 有证据表明,入耳PPG是评估生命体征的可靠方法.
相关概念视频
Pulse rhythm
833
Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
833
Pulse Oximetry
362
Pulse oximetry, or SpO2, is a non-invasive method for continuously monitoring arterial oxygen saturation (SaO2). This procedure involves attaching a probe or sensor to the patient's fingertip, forehead, earlobe, or nose bridge. The sensor works by detecting changes in oxygen saturation levels through light signals generated by the oximeter and reflected by the pulsing blood under the probe.
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
362
Guidelines For Measuring Vital Signs
1.7K
Following these guidelines can help nurses accurately measure vital signs, assess changes in patient conditions, and provide timely treatment when necessary. Adhering closely to the guidelines ensures the accuracy and reliability of the results.
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
1.7K
Assessment of Diffusion and Perfusion
1.0K
Understanding and evaluating diffusion and perfusion is critical in assessing a patient's respiratory and circulatory health. These processes play key roles in maintaining the body's internal environment, ensuring that tissues receive adequate oxygen while waste products are efficiently removed.
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
1.0K
Equipments Used To Measure Blood Pressure
1.1K
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
1.1K