一个替代的运动员监控系统,使用经济高效的惯性传感仪器仪表
Vicky Mudeng1,2, Imam M Hakim3, Sena S Suprapto2
1Department of Medical IT Convergence Engineering, Kumoh National Institute of Technology, Gumi, 39253 South Korea.
概括
惯性传感为监测运动表现提供了一种负担得起的方法. 这项研究表明,惯性测量单元如何跟踪步态参数,如步幅频率和运动分析的速度.
科学领域:
- 生物力学 生物力学
- 运动科学 运动科学 运动科学
- 可穿戴技术可穿戴技术
背景情况:
- 人类步态分析对于评估运动表现和识别潜在问题至关重要.
- 传统的方法,如GPS和视频分析可能是昂贵和繁的.
- 惯性测量单元 (IMU) 为运动跟踪提供了具有成本效益和便携性的解决方案.
研究的目的:
- 开发和验证使用惯性传感器的经济有效的体育监测系统.
- 评估IMU在跟踪关键步行参数方面的实时性能.
- 为了比较加速度计和陀螺仪数据的有效性,用于步态分析.
主要方法:
- 一个惯性传感器 (IMU) 被连接到运动员的右腿上.
- 加速度计测量了走路和跑步期间的腿角.
- 陀螺仪处理数据以确定步骤频率,并启用时间到频率域转换.
- 计算了步数和线性速度的数量.
- 使用统计假设测试来验证结果.
主要成果:
- IMU成功地实时跟踪了四个关键步行参数.
- 加速度计数据提供了有关腿部角度的见解.
- 陀螺仪数据准确地确定了步伐频率.
- 计算的步数和线性速度得到了统计验证.
- 该系统在体育监测方面表现出了有前途的性能.
结论:
- 惯性传感为体育监测提供了一个可行的,负担得起的替代方案.
- IMU可以有效地捕获运动员必不可少的步态指标.
- 这项技术有可能增强体育表现分析和伤害预防.
相关概念视频
Equipments Used to Measure Body Temperature
Body temperature can be assessed using various devices and measured in Celsius or Fahrenheit.
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Equipments Used To Measure Blood Pressure
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...


