基于相变材料的离子电池热管理系统的参数效应量化
1Department of Chemical Engineering, Faculty of Engineering and Architecture, Eskişehir Osmangazi University, Eskişehir, Turkey.
Turkish journal of chemistry
|August 2, 2023
概括
变相材料 (PCM) 显著降低离子电池的最大温度,超过放电率和环境温度效应. 这项研究有助于开发先进的电池冷却系统.
科学领域:
- 材料科学 材料科学 材料科学
- 电化学 电化学 电化学
- 热力工程是热力工程中的一个.
背景情况:
- 离子电池在高速放电过程中产生大量热量.
- 有效的热管理对于电池性能和安全至关重要.
- 换相材料 (PCM) 为热管理提供了被动冷却解决方案.
研究的目的:
- 为了研究放电率,环境温度和PCM对电池最大温度和温度差异的影响.
- 量化每个参数对热行为的影响.
- 为优化基于PCM的电池冷却系统提供数据.
主要方法:
- 在不同的放电率 (4C,5C) 和环境温度 (310K,320K) 下,对14.6Ah离子电池进行实验测试.
- 使用PCM和不使用PCM的电池热性能比较.
- 对最大温度和温度差异的参数影响的定量分析.
主要成果:
- 在5C放电和320K环境温度下,PCM将电池的最大温度从327.94K降低到306.45K.
- PCM对最大温度的影响比放电速率或环境温度更大.
- 环境温度对最大温度 (2.5倍摄氏度) 和温度差 (50倍摄氏度) 的影响比排放速度更大.
结论:
- 变相材料在缓解电池峰值温度方面非常有效.
- 环境温度是影响电池热管理的关键因素.
- 量化参数效应使得改进的PCM电池热管理系统的设计成为可能.
更多相关视频
11:25Identification and Quantification of Decomposition Mechanisms in Lithium-Ion Batteries; Input to Heat Flow Simulation for Modeling Thermal Runaway
Published on: March 7, 2022
4.6K
10:41The Effect of Charging and Discharging Lithium Iron Phosphate-graphite Cells at Different Temperatures on Degradation
Published on: July 18, 2018
15.5K
相关概念视频
PID Controller
146
Proportional-Integral-Derivative (PID) controllers are widely used in various control systems to enhance stability and performance. In a thermostat, it adjusts heating or cooling based on the temperature difference between the actual and desired levels. They are often used in automotive speed systems, effectively managing sudden speed changes while maintaining a constant speed under varying conditions. On the other hand, PI controllers, commonly employed in voltage regulation, enhance stability...
146
Phase Changes
4.4K
Phase transitions play an important theoretical and practical role in the study of heat flow. In melting or fusion, a solid turns into a liquid; the opposite process is freezing. In evaporation, a liquid turns into a gas; the opposite process is condensation.
A substance melts or freezes at a temperature called its melting point and boils or condenses at its boiling point. These temperatures depend on pressure. High pressure favors the denser form of the substance, so typically, high pressure...
A substance melts or freezes at a temperature called its melting point and boils or condenses at its boiling point. These temperatures depend on pressure. High pressure favors the denser form of the substance, so typically, high pressure...
4.4K
Le Chatelier's Principle: Changing Temperature
29.8K
Consistent with the law of mass action, an equilibrium stressed by a change in concentration will shift to re-establish equilibrium without any change in the value of the equilibrium constant, K. When an equilibrium shifts in response to a temperature change, however, it is re-established with a different relative composition that exhibits a different value for the equilibrium constant.
To understand this phenomenon, consider the elementary reaction:
To understand this phenomenon, consider the elementary reaction:
29.8K
Time and frequency -Domain Interpretation of Phase-lead Control
103
Phase-lead controllers are commonly used in various control systems to enhance response speed and stability. Adjusting the brightness on a television screen offers a practical example of phase-lead control. When contrast is enhanced, a phase-lead controller is employed. Mathematically, phase-lead control is identified when the first parameter is smaller than the second.
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
103
Phase-lead and Phase-lag Controllers
199
Understanding the working function of different types of controllers can be illustrated with practical analogies, such as adjusting a stereo's volume equalizer. Cranking up the bass involves a phase-lead controller, which functions as a high-pass filter, while increasing the treble uses a phase-lag controller, which acts as a low-pass filter. PD controllers, similar to high-pass filters, enhance the system's response to high-frequency components. PI controllers, akin to low-pass...
199
Heating and Cooling Curves
22.9K
When a substance—isolated from its environment—is subjected to heat changes, corresponding changes in temperature and phase of the substance is observed; this is graphically represented by heating and cooling curves.
For instance, the addition of heat raises the temperature of a solid; the amount of heat absorbed depends on the heat capacity of the solid (q = mcsolidΔT). According to thermochemistry, the relation between the amount of heat absorbed or released by a substance, q, and its...
For instance, the addition of heat raises the temperature of a solid; the amount of heat absorbed depends on the heat capacity of the solid (q = mcsolidΔT). According to thermochemistry, the relation between the amount of heat absorbed or released by a substance, q, and its...
22.9K