在中风装置设置中的心房动检测的数据库启用质量控制
Mario E Andina1, Alexander Nelde1, Christian H Nolte1,2,3,4
1Department of Neurology, Charité - Universitätsmedizin Berlin, Berlin, Germany.
Heliyon
|August 3, 2023
概括
在中风患者中,自动心房动 (AF) 报警是有效的,但需要临床团队对错过诊断进行审查. 改善AF检测可以加强二次预防策略.
科学领域:
- 心脏病学和神经病学
- 医疗信息学 医疗信息学
- 临床试验方法论 临床试验方法论
背景情况:
- 心房动 (AF) 是急性中风患者的常见并发症.
- 持续监测AF对于及时诊断和治疗至关重要.
- 用于AF报警的标准操作程序 (SOP) 需要在临床实践中进行验证.
研究的目的:
- 在临床实践中评估心房动 (AF) 报警标准操作程序 (SOP) 的准确性.
- 评估住院急性中风患者自动连续AF监测的性能.
- 为了确定错过的AF诊断及其对抗凝血剂治疗启动的影响.
主要方法:
- 追溯队列研究涉及109名急性缺血性中风患者,有AF报警.
- 围绕AF警报的ECG数据段从临床数据仓库下载.
- 手动审查将心电图段分类为AF,非AF或文物;数据与电子健康记录进行交叉引用.
主要成果:
- 在3.7%的患者中,尽管出现了真正的积极警报,但临床团队错过了AF.
- 所有错过AF诊断的患者都没有接受抗凝药治疗.
- 自动AF检测系统的正预测值 (PPV) 为0.6.
结论:
- 自动化AF监控系统是有效的,但需要临床团队的监督,以防止错过诊断.
- 在中风治疗期间检测AF的既定SOP是有效的,但提供了改进的机会.
- 数据仓库集成的方法可以提高AF监控质量,并确定过程优化的领域.
更多相关视频
08:10Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
1.7K
28:13Catheter Ablation in Combination With Left Atrial Appendage Closure for Atrial Fibrillation
Published on: February 26, 2013
33.5K
相关概念视频
Dysrhythmias V: Evaluating Dysrhythmias
42
Dysrhythmias, also known as arrhythmias, are disturbances in the heart's rhythm that range from benign to life-threatening. A thorough evaluation is crucial for appropriate management and involves a comprehensive medical history, physical examination, and various diagnostic tests.Medical HistorySymptoms: Collect detailed information on palpitations, dizziness, syncope, chest pain, and fatigue. Note their onset, frequency, and triggers.Previous Cardiac Issues: Document any history of heart...
42
Pulse rhythm
833
Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
833
Assessing Blood pressure using a doppler ultrasound
1.4K
To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
1.4K