削减上限政策对电力系统脱碳的意想不到的影响
Yongbin Ding1, Mingquan Li1,2, Ahmed Abdulla3
1School of Economics and Management, Beihang University, Beijing 100191, China.
iScience
|August 3, 2023
概括
电力系统的削减上限阻碍了脱碳目标. 这种政策增加了成本和二氧化碳排放,同时减少了可再生能源的容量,并危及了电网的可靠性.
科学领域:
- 电力系统工程 电力系统工程
- 环境科学 环境科学
- 能源政策 能源政策
背景情况:
- 各国正在减碳电力系统,以应对气候变化.
- 严格的整合目标,如缩减上限,在一些地区实施,如中国.
- 这些限制上限对电力系统脱碳的影响仍未得到充分研究.
研究的目的:
- 评估削减上限对省级电力系统脱碳的影响.
- 分析这些上限对可再生能源整合,电网可靠性和经济成本的影响.
主要方法:
- 利用容量扩展模型来模拟省级电力系统.
- 评估了不同限制上限水平对系统配置和运行的影响.
- 可再生能源容量,储能容量,发电组合和排放量的量化变化.
主要成果:
- 限制上限显著增加了所需的储能容量 (+43%,5%上限),同时减少了可再生能源容量 (-17%).
- 尽管存储量增加,但电力系统的可靠性受到损害,导致更频繁的过量和不足发电事件.
- 水力发电被抑制,储能利用率下降,化石燃料使用量在限制上限下增加.
- 实施5%的减排上限会导致经济成本增加6%,二氧化碳排放增加7%.
结论:
- 限制上限具有不利影响,与其旨在促进可再生能源整合的目的相矛盾.
- 这些政策可能无意中增加成本和排放,并降低整体系统的效率和可靠性.
- 应考虑替代策略来实现电力系统脱碳,这些策略不依赖于严格的减排限制.
相关概念视频
Control of Power Flow
290
There are several methods to control power flow in power systems:
290
Power Factor Correction
207
The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
207
Fast Decoupled and DC Powerflow
233
The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
233
Reclosers and Fuses
129
Automatic circuit reclosers enhance the protection of distribution circuits by interrupting and auto-reclosing an AC circuit according to a preset sequence. They effectively manage temporary faults on overhead distribution lines, often caused by tree limbs or wildlife, by briefly disrupting service to improve overall reliability. However, contact with reclosers or energized broken conductors on the ground can pose serious hazards.
A comprehensive protection scheme for radial distribution...
A comprehensive protection scheme for radial distribution...
129
Load-frequency control
193
Load-frequency control (LFC) is vital for maintaining power system stability, ensuring that frequency and power flows remain within acceptable limits during load changes. Turbine-governor control eliminates rotor accelerations and decelerations following load changes. However, a steady-state frequency error persists when the change in the turbine-governor reference setting is zero. In an interconnected power system, each area agrees to export or import a scheduled amount of power through...
193
Conservation of AC Power
356
The principle of power preservation is applicable to both ac and dc circuits. This principle, when applied to AC power, asserts that the complex, real, and reactive powers produced by the source are equal to the total complex, real, and reactive powers absorbed by the loads. When two load impedances are connected in parallel to an ac source V, the complex power provided by the source can be calculated using the relation
356