收回:基于人工智能的应用在变电站运行和维护管理中的应用
Computational intelligence and neuroscience
|August 4, 2023
概括
这项研究已被撤回. 标识DOI 10.1155/2022/7509532的文章不再被认为是有效的科学文献.
科学领域:
- 撤销科学出版物的撤销.
- 学术诚信 学术诚信
背景情况:
- 标签为DOI 10.1155/2022/7509532的文章已被收回.
- 撤回对于保持科学准确性至关重要.
研究的目的:
- 正式宣布撤回一个特定的科学文章.
- 通知科学界关于已发表的研究无效的通知.
主要方法:
- 撤回是基于未披露的原因.
- 通过期刊的编辑过程进行正式通知.
主要成果:
- 这篇文章DOI: 10.1155/2022/7509532 正式撤回.
- 文章中提出的发现和结论不再被认为是有效的.
结论:
- 收回的文章不应被引用或用于进一步的研究.
- 保持科学记录的完整性至关重要.
相关概念视频
Distribution Reliability and Automation
130
Distribution reliability in electrical power systems is critical for ensuring an uninterrupted power supply to consumers at minimal cost. According to IEEE Standard Terms, reliability is the probability that a device will function without failure over a specified time period or amount of usage. For electric power distribution, this translates to maintaining continuous power supply and addressing customer concerns over power outages. Several indices, as defined by IEEE Standard 1366-2012, are...
130
Reclosers and Fuses
129
Automatic circuit reclosers enhance the protection of distribution circuits by interrupting and auto-reclosing an AC circuit according to a preset sequence. They effectively manage temporary faults on overhead distribution lines, often caused by tree limbs or wildlife, by briefly disrupting service to improve overall reliability. However, contact with reclosers or energized broken conductors on the ground can pose serious hazards.
A comprehensive protection scheme for radial distribution...
A comprehensive protection scheme for radial distribution...
129
Power System Three-Phase Short Circuits
111
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
111
Transformers in Distribution System
124
Transformers in distribution systems can be broadly categorized into distribution substation transformers and other distribution transformers. They are crucial for stepping down high transmission voltages to levels suitable for distribution and end-user applications.
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
124
Multimachine Stability
191
Multimachine stability analysis is crucial for understanding the dynamics and stability of power systems with multiple synchronous machines. The objective is to solve the swing equations for a network of M machines connected to an N-bus power system.
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
191
Load-frequency control
193
Load-frequency control (LFC) is vital for maintaining power system stability, ensuring that frequency and power flows remain within acceptable limits during load changes. Turbine-governor control eliminates rotor accelerations and decelerations following load changes. However, a steady-state frequency error persists when the change in the turbine-governor reference setting is zero. In an interconnected power system, each area agrees to export or import a scheduled amount of power through...
193


