三倍三倍的消灭升级基于转换的氧气传感器来克服自发光的局限性
Adrian A Mendonsa1, Cassandra C Soeldner1, Natalie E Mudd2
1Chemical and Biological Engineering, Colorado School of Mines, Golden, Colorado 80401, United States.
ACS sensors
|August 4, 2023
概括
这项研究引入了一种新的纳米传感器,利用向上转换来测量生物系统中溶解的氧气. 这项技术有效地克服了自光干扰,使酵母中的代谢活动能够得到更清晰的监测.
科学领域:
- 生物成像和纳米传感器技术
- 生物物理化学 生物物理化学
- 代谢活动监测 代谢活动监测
背景情况:
- 生物成像中的自发光构成了一个重大挑战,它会掩盖来自光探针和标记器的信号.
- 向上转换提供了一种潜在的解决方案,可以克服生物成像中的自流光限制.
- 精确监测溶解氧气对于了解细胞代谢过程至关重要.
研究的目的:
- 开发一种能够光学报告溶解氧度变化的纳米传感器.
- 为了利用三倍三倍的消灭升级转换来克服生物成像中的自流体.
- 通过跟踪氧气消耗来监测Saccharomyces cerevisiae中的代谢活动.
主要方法:
- 一个纳米传感器的开发基于三倍三倍的消灭上转换.
- 使用一种敏感剂-消灭剂染料对: (II) 八甲基和9,10-二乙.
- 随着时间的推移,监测Saccharomyces cerevisiae中的氧气消耗.
主要成果:
- 纳米传感器对0.00至3.17毫克/升O2.2的溶解氧水平表现出敏感性.
- 传感器在多个周期中表现出良好的可逆性,并保持了7天的信号和体稳定性.
- 在纳米传感器发射和酵母自身光之间没有观察到信号重叠.
结论:
- 向上转换提供了一种简单且经济的方法,可以在生物成像中克服自身光.
- 开发的纳米传感器有效监测生物系统中溶解氧和代谢活动.
- 这项技术对需要增强信号检测的先进生物成像应用具有前景.
更多相关视频
10:38Synthesis and Calibration of Phosphorescent Nanoprobes for Oxygen Imaging in Biological Systems
Published on: March 3, 2010
14.0K
11:26Integrating a Triplet-triplet Annihilation Up-conversion System to Enhance Dye-sensitized Solar Cell Response to Sub-bandgap Light
Published on: September 12, 2014
12.6K
相关概念视频
Fluorescence and Phosphorescence: Instrumentation
648
Fluorometers and spectrofluorometers are two types of instruments used for measuring molecular fluorescence. These instruments differ in how they select excitation and emission wavelengths and the type of light sources they utilize. Fluorometers use absorption interference filters to choose excitation and emission wavelengths. The excitation source in a fluorometer is typically a low-pressure mercury vapor lamp that emits intense lines distributed throughout the ultraviolet and visible regions.
648
Photoluminescence: Fluorescence and Phosphorescence
2.1K
Photoluminescence is a process where a molecule absorbs light energy and re-emits it in the form of light. This phenomenon occurs when a substance absorbs photons, promoting its electrons to higher energy level excited states, followed by a relaxation process in which the electrons return to their original ground state energy levels and emit light. Photoluminescence is widely observed in various materials, including semiconductors, and organic and inorganic compounds.
A pair of electrons in a...
A pair of electrons in a...
2.1K
Super-resolution Fluorescence Microscopy
7.1K
Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been...
7.1K