相关实验视频
Updated: Jul 19, 2025

07:06
Binocular Dynamic Visual Acuity in Eyeglass-Corrected Myopic Patients
Published on: March 29, 2022
2.6K
一个数据驱动的距离度量,用于评估动态范围压缩在不利条件下的影响
Niels Overby1, Torsten Dau1, Tobias May1
1Hearing Systems Section, Department of Health Technology, Technical University of Denmark, Kgs. Lyngby, Denmark.
Trends in hearing
|August 10, 2023
概括
现场感知式助听器压缩适应声条件,优于传统的快速起作用和缓慢起作用系统. 这种适应性方法为听力受损的听众在各种环境中提供了潜在的好处.
科学领域:
- 听力学 听力学是指听力学.
- 信号处理 信号处理
- 声学 声学 在声学上
背景情况:
- 动态范围压缩在助听器中至关重要,以改善听力损失的个体的听力.
- 最佳的压缩参数选择,特别是时间常数,由于在声条件下不同的感知效益而受到争论.
研究的目的:
- 开发数据驱动的距离度量,使用物理度量来评估和比较不同的助听器压缩系统.
- 评估在各种声环境下快速作用,缓慢作用,现场感知和源独立压缩的性能.
主要方法:
- 开发了一种基于物理指标的新型距离度量.
- 使用因子分析来减少维度,并从客观指标中推导可解释的特征.
- 为了比较压缩系统,曼哈顿距离应用于减少的特征空间.
主要成果:
- 与快速作用和缓慢作用的压缩相比,现场感知压缩显示了与参考 (源独立) 系统的距离较小.
- 压缩系统的性能在不同噪音水平和反响下进行了评估.
结论:
- 适应性,现场意识的压缩显示了提高助听器性能在一系列声学条件的承诺.
- 开发的距离度量为客观评估和比较压缩策略提供了有价值的工具.
相关概念视频
Distance Corrections
50
To achieve precise distance measurements, especially in surveying and construction, certain corrections must be applied to account for potential sources of error like the standardization errors, temperature variations, and slope adjustments.Standardization error emerges when measurement equipment undergoes changes, such as wear, repairs, or weather impacts. To address this, surveyors compare the equipment’s readings to a standard. This process identifies any deviation that might lead to...
50
Difference from Background: Limit of Detection
6.4K
The limit of detection (LOD) is the smallest amount of analyte that can be distinguished from the background noise. The LOD value corresponds to the concentration at which the analyte signal is three times larger than the standard deviation of the blank signal. Below this value, the analyte signal cannot be differentiated from the background noise. It is calculated by dividing the calibration slope by 3 times the standard deviation of the blank signals.
The LOD indicates the presence or absence...
The LOD indicates the presence or absence...
6.4K
Distance Measurements by Taping
66
Tapes are essential in surveying for accurate, durable, and short-distance measurements. Made from lightweight, nylon-coated steel, they offer flexibility and strength for rugged outdoor use. The nylon coating protects against rust and wear, extending the tape's life. Standard lengths, around 30 meters, are marked in meters and millimeters for precision.Surveyors select tapes based on site conditions and accuracy needs. Lightweight, nylon-coated tapes are commonly used for ease of handling and...
66
Dynamic Modulus of Elasticity of Concrete
393
The dynamic modulus of elasticity assesses how a concrete structure deforms under impact or dynamic loads. It is typically higher than the static modulus of elasticity, measured under slow, steady loading conditions.
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by...
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by...
393
Mean Absolute Deviation
2.7K
The mean absolute deviation is also a measure of the variability of data in a sample. It is the absolute value of the average difference between the data values and the mean.
Let us consider a dataset containing the number of unsold cupcakes in five shops: 10, 15, 8, 7, and 10. Initially, calculate the sample mean. Then calculate the deviation, or the difference, between each data value and the mean. Next, the absolute values of these deviations are added and divided by the sample size to...
Let us consider a dataset containing the number of unsold cupcakes in five shops: 10, 15, 8, 7, and 10. Initially, calculate the sample mean. Then calculate the deviation, or the difference, between each data value and the mean. Next, the absolute values of these deviations are added and divided by the sample size to...
2.7K
Electronic Distance Measuring Instruments
59
Electronic Distance Measuring Instruments (EDMs) are essential tools in modern surveying, offering precise distance measurements by emitting electromagnetic signals and calculating the time required for these signals to travel to a target and return. Two primary types of signals are used in EDMs — light waves and microwaves — each suited to specific environmental and distance requirements. Light-wave-based EDMs utilize either infrared or laser light, providing high accuracy over short...
59

