一种简单的电压测量方法,通过确定纤维素的测量来评估射击距离
Antonella Profumo1, Andrea Capucciati1, Alessia Mattino1
1Dipartimento di Chimica, Università degli Studi di Pavia, 27100 Pavia, Italy.
Talanta
|August 11, 2023
概括
在枪击目标中对酸纤维素 (NC) 的法医分析至关重要. 一种新的微分脉冲电量计方法量化NC,通过分析其度衰减在目标上,使得射击距离的估计.
科学领域:
- 法医科学 法医科学 法医科学
- 分析化学 分析化学
- 电化学 电化学 电化学
背景情况:
- 亚纤维素 (NC) 是小型枪支弹药中的主要推进剂.
- 在射击过程中喷射出NC粒子,可以在目标上找到.
- 定量分析和电化学测定NC用于法医目的是不发达的.
研究的目的:
- 开发一种定量差脉冲电压测量方法,用于法医目标中的NC分析.
- 通过测量目标上的NC度衰变来估计射击距离.
- 评估方法的性能和潜在的干扰.
主要方法:
- 差异脉冲电压测量 (DPV) 用于定量NC分析.
- 这种方法使用了乙二/乙醇/甲溶剂系统.
- 弹药在不同距离 (5-120厘米) 发射,以创建校准曲线.
主要成果:
- 该DPV方法实现了量化限值 (LOQ) 的4毫克L-1和线性到2000毫克L-1.1.
- 建立了一个校准曲线,将NC度衰减与射击距离相关联.
- 评估了潜在干扰物的影响,如水,酸甘,酸甘和酸盐.
结论:
- 成功开发了一种新而敏感的电化学方法,用于法医应用中量化纤维素.
- 该方法可以根据对目标的剩余NC度来估计射击距离.
- 这种技术为涉及枪支证据的法医调查提供了有价值的工具.
更多相关视频
相关概念视频
Voltammetric Techniques: Pulse Voltammetry
579
Differential-pulse voltammetry (DPV) is a type of voltammetry that involves applying a series of voltage pulses to an electrochemical cell while measuring the resulting current. In DPV, the differential pulse or small potential pulses are superimposed on a linear potential sweep. The magnitude of these pulses is typically small, often in the millivolt range. Each voltage pulse lasts a short duration, usually in the order of a few milliseconds, and is applied at regular intervals along the...
579
Voltammetry: Overview
1.8K
Voltammetry is an electroanalytical technique in which the current flowing through an electrochemical cell is measured as a function of applied potential, typically under conditions of concentration polarization. The technique provides valuable information about redox-active species, and the current response is plotted as a voltammogram.
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
1.8K
Voltammetric Techniques: Linear-Scan (E vs Time)
435
Polarography is a classical voltammetric technique used to analyze electrochemical reactions. This method applies a linear potential sweep to a dropping mercury electrode (DME), and the resulting current is measured. A dropping mercury electrode is commonly used as the working electrode in polarography. It consists of a capillary tube filled with mercury, where the tiny droplet forms at the tip. This droplet continuously drops from the capillary, creating a new electrode surface for each...
435
Flame Photometry: Lab
275
In a flame photometer, when a solution like potassium chloride is aspirated into the flame, the solvent evaporates, leaving behind dehydrated salt. This salt dissociates into free gaseous atoms in their ground state. Some of these atoms absorb energy from the flame, leading to their excitation. The excited atoms return to the ground state, emitting photons at characteristic wavelengths. Because only electronic transitions are involved, the resulting emission lines are very narrow. The intensity...
275
Precipitation Gravimetry
6.7K
Precipitation gravimetry is based on converting an analyte into a sparingly soluble precipitate, which is separated by filtration and weighed. An ideal precipitate should be pure, insoluble, of known composition, and easily filtered from the reaction mixture.
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...
6.7K
Voltammetry: Factors Affecting Measurements
180
A current produced due to the redox reactions of the analyte at the working and auxiliary electrodes is called a faradaic current. The reaction can be divided into two types. The current generated due to the reduction of the analyte is called cathodic current, and it carries a positive charge. In contrast, the current produced by analyte oxidation is known as an anodic current, and it has a negative charge. The applied potential at the working electrode determines the faradaic current flow, and...
180