在InfraNet:准确的额头温度测量框架为人们在野外的单眼热红外摄像机
Xichuan Zhou1, Dongshan Lei1, Chunqiao Long1
1School of Microelectronics and Communication Engineering, Chongqing University, Chongqing 400044, China.
概括
这项研究介绍了InfraNet,这是一种新的单眼热成像系统,用于在流行病期间准确的远程人体温度查. 在不影响隐私的情况下,InfraNet通过测量额头温度来增强疾病监测,达到91.6%的准确率.
科学领域:
- 计算机视觉 计算机视觉
- 生物医学工程 生物医学工程
- 流行病学 流行病学
背景情况:
- 精确的人体温度查对于流行病期间的疾病监测至关重要.
- 现有的双摄像头系统由于使用RGB图像,引发了隐私问题.
- 远程额头温度测量面临着温度波动等挑战.
研究的目的:
- 开发一个保护隐私的单眼热系统,用于准确的远程额头温度测量.
- 引入用于使用深度和水平偏移校准温度的InfraNet框架.
- 通过可靠,非侵入性温度查,提高疾病监测能力.
主要方法:
- 设计了一个单眼热成像系统和InfraNet框架.
- InfraNet使用面部检测,深度/偏移估计和温度校准子网络.
- 采用空间规范化术语来准确地预测深度和偏移.
- 在实验室和野生环境中收集了8215张热红外图像的大规模数据集.
主要成果:
- 基础网络框架在额头温度测量方面表现出高准确度.
- 平均在远程多个对象温度测量中达到91.6%的准确性.
- 在严格的温度值 (0.3°C) 下,在大型数据集上验证了性能.
结论:
- InfraNet为远程温度选提供了一种有效且对隐私有意识的解决方案.
- 该系统使用物理深度和偏移校准来解决温度浮动的挑战.
- 这项技术可以显著提高流行病期间的公共卫生监测.
相关概念视频
Temperature Measurement Sites
1.8K
A thermometer measures body temperature. The common sites for measuring body temperature are the oral cavity, axillary region, temporal artery, and skin surface, such as the forehead, abdomen, and axilla. True core body temperature is assessed in the rectum, tympanic membrane, pulmonary artery, esophagus, and urinary bladder.
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
1.8K
Assessing Body Temperature - Temporal Artery
586
Here is a stepwise guide to assessing the body temperature at the temporal artery using a temporal artery thermometer
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
586
Equipments Used to Measure Body Temperature
1.1K
Body temperature can be assessed using various devices and measured in Celsius or Fahrenheit.
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
1.1K
Assessing Body Temperature - Tympanic membrane
614
Assessing tympanic membrane temperature involves using a tympanic membrane thermometer (TMT). Here is a step-by-step guide:
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
614
Assessing Body Temperature - Axilla
614
Procedural Guide for Assessing Axillary Body Temperature using a Digital Thermometer:
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
614
Assessing Body Temperature - Oral
772
Here are the steps to accurately measure oral temperature using an electronic thermometer:
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
772