握力与贾马尔相比:评估握力强度的新动力仪的挑战
Cédric Villain1, Soazig Lebaube2, Corinne Kremer2
1Department of Geriatric Medicine, Centre Hospitalier Universitaire de Caen Normandie, Normandie Univ., UNICAEN, INSERM U1075, COMETE, Caen, France.
概括
Gripwise设备与Jamar对老年人手握强度 (HGS) 评估的测试有很好的相关性. 然而,较低的Gripwise读数需要调整切断值以准确诊断肉症.
科学领域:
- 老年学是一门学科.
- 临床诊断 临床诊断 临床诊断
- 肌肉骨健康 肌肉骨健康
背景情况:
- 萨科佩尼亚的诊断部分依赖于手握强度 (HGS) 的评估.
- 贾马尔动力表是黄金标准,而Gripwise提供了一个便携式替代品.
- 之前的实验室测试显示,Gripwise的测量与Jamar的测量相关.
研究的目的:
- 为了确认Gripwise和Jamar HGS测量在老年住院患者之间的相关性.
- 确定Gripwise是否可以可靠地用于临床环境中的HGS评估,以诊断肉类病.
主要方法:
- 一个单中心的横截面研究包括348名65岁及以上的住院患者.
- 参与者被随机分配使用Jamar或Gripwise设备开始测量.
- 计算了最大值和平均值的类内相关系数 (ICC).
主要成果:
- 在Jamar和Gripwise之间发现了很高的相关性 (最大值为ICC=0.93,平均值为0.94).
- 与Jamar (48%) 相比,Gripwise在较高比例的患者中发现了低HGS (71%).
- 用于Gripwise的替代切断值 (女性<12公斤,男性<22公斤) 显示出高的诊断性能.
结论:
- Gripwise设备是老年住院患者HGS评估的可靠工具,与Jamar有很强的相关性.
- 对Gripwise进行调整的诊断断断线是必要的,以便在这个人群中准确识别手握强度低和肉眼症.
相关概念视频
Assessment of blood pressure in brachial artery(two-step method)
758
Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
758
Assessment of blood pressure in brachial artery(one-step method)
636
This procedural guide systematically measures blood pressure using an oscillometric digital sphygmomanometer, emphasizing accuracy, patient safety, and comfort.
Prepare for the Procedure:
Prepare for the Procedure:
636
Assessment of radial pulse
872
Assessment of Radial Pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
872
Comparison Between Electrical And Gravitational Forces
2.7K
There are four fundamental forces in nature: the gravitational force, the electromagnetic force, the strong nuclear force, and the weak nuclear force. To compare the numerical strengths of the first two, take two particles of the same kind. Since electrons are fundamental particles, they are a good example.
Since both are inverse square law forces, the distance gets canceled when the ratio of the two forces is considered. Instead, the ratio of the electrical and gravitational forces depends on...
Since both are inverse square law forces, the distance gets canceled when the ratio of the two forces is considered. Instead, the ratio of the electrical and gravitational forces depends on...
2.7K
Equipments Used To Measure Blood Pressure
1.1K
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
1.1K
Assessment of the Cardiovascular System III: Palpation
378
Palpation involves feeling the body to evaluate texture, size, consistency, and tenderness for assessing cardiovascular health. The following steps are organized in a head-to-toe order:
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
378