表面化学应用和使用电化学阻抗光谱的免疫传感器的开发:全面的审查
Caoimhe Robinson1, Vuslat B Juska1, Alan O'Riordan1
1Tyndall National Institute, University College Cork, T12 R5CP, Cork, Ireland.
Environmental research
|August 14, 2023
概括
电化学免疫传感器为癌症等疾病提供了敏感的检测. 本综述详细介绍了使用电化学阻抗光谱 (EIS) 构建有效的阻抗度免疫传感器的关键组件.
科学领域:
- 电化学 电化学 电化学
- 生物感应是一种生物感应.
- 分析化学 分析化学
背景情况:
- 电化学免疫传感器是先进的检测平台,为COVID-19,癌症和阿尔茨海默病等疾病提供敏感和选择性的生物标志物识别.
- 电化学阻抗光谱 (EIS) 是一种高度敏感的电化学技术,用于分析各种频率的阻抗.
研究的目的:
- 审查构建成功阻隔度免疫传感器所必需的基本组件和协议.
- 突出表面化学和固定化策略对免疫传感器性能的影响.
主要方法:
- 关于阻隔度免疫传感器构建的文献综述.
- 包括自组装单层,纳米材料和聚合物在内的关键构件的概述.
- 讨论固定化方案和抗体定向策略.
主要成果:
- 成功的阻抗测量免疫传感器开发依赖于仔细选择表面化学和固定方法.
- 纳米材料和聚合物等各种材料显著提高了传感器的性能.
- 优化抗体定向对于最大限度地提高灵敏度和选择性至关重要.
结论:
- 使用EIS的阻抗测量免疫传感器是传统诊断方法的有希望的替代方案.
- 了解和控制免疫传感器的构建块对于优化电分析性能至关重要.
- 对表面化学,材料和固定技术的进一步研究将推动免疫传感器技术的发展.
更多相关视频
相关概念视频
Interfacial Electrochemical Methods: Overview
286
Interfacial electrochemical methods focus on the phenomena occurring at the boundary between an electrode and a solution, as opposed to bulk methods that concentrate on the solution's overall properties. These interfacial methods are classified as either static or dynamic based on the presence of a nonzero current in the electrochemical cell and the consistency of analyte concentrations. Static methods, such as potentiometry, measure the cell's potential without any significant current...
286
Enzyme-Linked Immunosorbent Assay
13.5K
In 1971, Peter Perlman and Eva Engvall developed an Enzyme-linked immunosorbent assay (ELISA or EIA). ELISA differs from western blot in that the assays are conducted in microtiter plates or in vivo rather than on an absorbent membrane.
There are many different types of ELISAs, but they all involve an antibody molecule whose constant region binds an enzyme, leaving the variable region free to bind its specific antigen. Enzyme-substrate reaction allows the antigen to be visualized or...
There are many different types of ELISAs, but they all involve an antibody molecule whose constant region binds an enzyme, leaving the variable region free to bind its specific antigen. Enzyme-substrate reaction allows the antigen to be visualized or...
13.5K
Potentiometry: Membrane Electrodes
632
Membrane electrodes, also known as p-ion electrodes, use membranes that selectively interact with free analyte ions, generating a potential difference across the membrane. The resulting membrane potential, known as the asymmetry potential, is not zero even when analyte concentrations on both sides of the membrane are equal. The membrane's response is typically not selective to a single analyte but proportional to the concentration of all ions in the sample solution capable of interacting at...
632
Electrospray Ionization (ESI) Mass Spectrometry
916
Higher molecular weight biomolecules are nonvolatile compounds that may decompose before ionizing or vaporizing during mass analysis with conventional electron impact ionization methods. Accordingly, electrospray ionization (ESI) is the favored method for vaporizing and ionizing biomolecules as it circumvents rapid fragmentation and enables the recording of mass signals for the entire biomolecule.
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
916