Jove
Visualize
联系我们
JoVE
x logofacebook logolinkedin logoyoutube logo
关于 JoVE
概览领导团队博客JoVE 帮助中心
作者
出版流程编辑委员会范围与政策同行评审常见问题投稿
图书馆员
用户评价订阅访问资源图书馆顾问委员会常见问题
研究
JoVE JournalMethods CollectionsJoVE Encyclopedia of Experiments存档
教育
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab Manual教师资源中心教师网站
使用条款与条件
隐私政策
政策

相关概念视频

Temperature Measurement Sites01:14

Temperature Measurement Sites

1.8K
A thermometer measures body temperature. The common sites for measuring body temperature are the oral cavity, axillary region, temporal artery, and skin surface, such as the forehead, abdomen, and axilla. True core body temperature is assessed in the rectum, tympanic membrane, pulmonary artery, esophagus, and urinary bladder.
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
1.8K
Equipments Used to Measure Body Temperature01:13

Equipments Used to Measure Body Temperature

1.1K
Body temperature can be assessed using various devices and measured in Celsius or Fahrenheit.
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
1.1K
Thermometers and Temperature Scales01:22

Thermometers and Temperature Scales

5.6K
Any physical property that depends consistently and reproducibly on temperature can be used as the basis of a thermometer. For example, volume increases with temperature for most substances. This property is the basis for the common alcohol thermometer and the original mercury thermometers. Other properties used to measure temperature include electrical resistance, color, and the emission of infrared radiation.
As many physical properties depend on temperature, the variety of thermometers is...
5.6K
Assessing Body Temperature - Tympanic membrane01:14

Assessing Body Temperature - Tympanic membrane

614
Assessing tympanic membrane temperature involves using a tympanic membrane thermometer (TMT). Here is a step-by-step guide:
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
614
Electronic Distance Measuring Instruments01:30

Electronic Distance Measuring Instruments

59
Electronic Distance Measuring Instruments (EDMs) are essential tools in modern surveying, offering precise distance measurements by emitting electromagnetic signals and calculating the time required for these signals to travel to a target and return. Two primary types of signals are used in EDMs — light waves and microwaves — each suited to specific environmental and distance requirements. Light-wave-based EDMs utilize either infrared or laser light, providing high accuracy over short...
59
Physical Methods for Controlling Microbial Growth: Temperature01:23

Physical Methods for Controlling Microbial Growth: Temperature

49
Heat is a widely used method to control microbial growth by targeting and denaturing cellular proteins, thereby killing or inactivating microbes. This method's effectiveness is quantified using parameters such as the thermal death point (TDP), thermal death time (TDT), and decimal reduction time (D value). TDP represents the lowest temperature at which all microorganisms in a liquid suspension are eliminated within 10 minutes, whereas TDT is the time necessary to achieve sterilization at a...
49

您也可能阅读

相关文章

通过共同作者、期刊和引用图与本文相关的文章。

排序
Same author

The difference in scotopic and photopic pupil responses: a potential indicator for long-term glycemic management.

Frontiers in neurology·2026
Same author

An Adams' Arch -based anatomical classification system guiding internal fixation strategies for non-displaced femoral neck fractures in elderly patients: a finite element analysis.

BMC musculoskeletal disorders·2026
Same author

Intracellular assembly of artificial enzymes for cytoplasmic enantioselective Mannich reactions.

Nature communications·2026
Same author

Translating policy into practice: teacher agency amid cognitive and ecological constraints in enacting competency-based assessment.

Frontiers in psychology·2026
Same author

Co-exposure to environmental lead and hypertension exacerbates anxiety and depression via mtDNA-mediated cGAS phase separation.

Environmental pollution (Barking, Essex : 1987)·2026
Same author

Efficacy and safety of combined immune therapy for advanced cervical cancer: a systematic review and meta-analysis.

Frontiers in oncology·2026
Same journal

Gaussian-modulated continuous-variable quantum key distribution over 60 km fiber using an integrated silicon photonic receiver.

Optics letters·2026
Same journal

E2E-OCT: end-to-end joint learning model using optical coherence tomography images for vocal cord leukoplakia diagnosis.

Optics letters·2026
Same journal

Holographic generation of panoramic 3D scenes by concave ellipsoidal mirror reflection.

Optics letters·2026
Same journal

Dual-pilot phase recovery with pair-wise maximum-ratio combining for coherent PONs.

Optics letters·2026
Same journal

Mapping the whispering gallery modes of a CaF<sub>2</sub> disk resonator with half-tapered fibers to estimate the fundamental mode volume.

Optics letters·2026
Same journal

Quantitative estimation of deep-subwavelength scale via dark-field scattering axial energy concentration decay profiles.

Optics letters·2026
查看所有相关文章

相关实验视频

Updated: Jul 19, 2025

Fabrication and Testing of Photonic Thermometers
08:44

Fabrication and Testing of Photonic Thermometers

Published on: October 24, 2018

5.9K

微型GaN光电子温度传感器

Binju Wang, Kang Fu, Jianwei Fu

    Optics letters
    |August 15, 2023
    PubMed
    概括
    此摘要是机器生成的。

    这项研究介绍了一种使用化 (GaN) 芯片与塑料光纤 (POF) 集成的新型温度传感系统. 该系统通过测量反射光脉冲来检测温度变化,提供微型光电子解决方案.

    更多相关视频

    Method for Simultaneous fMRI/EEG Data Collection during a Focused Attention Suggestion for Differential Thermal Sensation
    06:33

    Method for Simultaneous fMRI/EEG Data Collection during a Focused Attention Suggestion for Differential Thermal Sensation

    Published on: January 5, 2014

    11.9K
    Light Spot-Based Assay for Analysis of Drosophila Larval Phototaxis
    07:16

    Light Spot-Based Assay for Analysis of Drosophila Larval Phototaxis

    Published on: September 27, 2019

    6.3K

    相关实验视频

    Last Updated: Jul 19, 2025

    Fabrication and Testing of Photonic Thermometers
    08:44

    Fabrication and Testing of Photonic Thermometers

    Published on: October 24, 2018

    5.9K
    Method for Simultaneous fMRI/EEG Data Collection during a Focused Attention Suggestion for Differential Thermal Sensation
    06:33

    Method for Simultaneous fMRI/EEG Data Collection during a Focused Attention Suggestion for Differential Thermal Sensation

    Published on: January 5, 2014

    11.9K
    Light Spot-Based Assay for Analysis of Drosophila Larval Phototaxis
    07:16

    Light Spot-Based Assay for Analysis of Drosophila Larval Phototaxis

    Published on: September 27, 2019

    6.3K

    科学领域:

    • 光电学是指光电子产品.
    • 材料科学 材料科学 材料科学
    • 传感器技术 传感器技术

    背景情况:

    • 微型光电子传感系统对于先进的应用至关重要.
    • 将塑料光纤 (POF) 与单体集成的发射器和接收器集成,提供了新的可能性.
    • 基于化 (GaN) 的光电子芯片适用于集成传感.

    研究的目的:

    • 提出并展示一种新的温度传感系统.
    • 将GaN光电子芯片与POF和反射器集成在一起.
    • 为了利用单立体集成的多个量子井 (MQW) 二极管进行传感.

    主要方法:

    • 使用相同的MQW结构将GaN光电子芯片与发射器和接收器进行单体集成.
    • 使用反射器根据温度诱导的变形调节光反射.
    • 将反射光合到POF中,以便由芯片接收器检测.
    • 读取温度信息作为电信号.

    主要成果:

    • 该系统成功地检测到从20.1°C到100°C的温度变化.
    • 在这个温度范围内,观察到光学诱导的电信号从-3.04μA变化为-3.13μA.
    • 证明了使用热变形用于光学传感的可行性.

    结论:

    • 单立体集成的GaN设备是光电子温度传感的一个有前途的平台.
    • 这种方法为小型传感系统提供了紧而高效的解决方案.
    • 进一步开发可能会导致在各种领域的广泛应用.