评估和工业互联网成熟度的治理在建筑材料行业使用权方法和因素分析
Yang Heng1, Chen Sheng1, Hu Youxue2
1School of Public and Administration, Chongqing University, Chongqing, China.
Heliyon
|August 18, 2023
概括
建筑材料公司的工业互联网成熟度主要处于基本阶段,具有强大的网络基础设施,但集成和数据分析能力较弱. 这项研究为该行业提供了第一个成熟度模型.
科学领域:
- 制造业 制造业 制造业 制造业
- 数字化的数字化
- 工业互联网 工业互联网 工业互联网
背景情况:
- 工业互联网对于数字化,网络化和制造业的创新至关重要.
- 建筑材料行业面临着高能耗和低效率等挑战.
研究的目的:
- 构建一个指数系统来评估工业互联网在建筑材料行业的成熟度.
- 为公司提供自我评估工具,指导政府决策.
主要方法:
- 使用因子分析和权方法创建了评估指数系统并分配权重.
- 对59家建筑材料公司进行实证研究.
主要成果:
- 确定了工业互联网成熟度的七个关键指标.
- 大多数大型公司都处于初级阶段 (2星级到期).
- 信息网络基础设施相对强大,但综合整合和数据分析较弱.
结论:
- 本研究为建筑材料行业提供了第一个工业互联网成熟度模型.
- 该模型通过确定数字化和整合方面的改进领域来解决行业的挑战.
相关概念视频
Factors Affecting Workability
91
The workability of concrete is a critical characteristic that influences the ease of mixing, handling, and finishing the concrete. It is affected by several factors including water content, aggregate properties, and admixtures like air entrainment. Water plays a fundamental role as it lubricates the concrete mix, facilitating easier movement and placement. However, the water requirement varies depending on the texture and shape of aggregates. Finer particles and angular, rough-textured...
91
Factors Affecting Activity Coefficient
832
The extended Debye-Hückel equation indicates that the activity coefficient of an ion in an aqueous solution at 25°C depends on three partially interdependent properties: the ionic strength of the solution, the charge of the ion, and the ion size.
The activity coefficient value for an ion is close to one when the solution has almost zero ionic strength, i.e., when the solution shows close to ideal behavior. As the ionic strength of the solution increases from 0 to 0.1 mol/L, a...
The activity coefficient value for an ion is close to one when the solution has almost zero ionic strength, i.e., when the solution shows close to ideal behavior. As the ionic strength of the solution increases from 0 to 0.1 mol/L, a...
832
Measurement of Air Content in Concrete
183
Air content measurement in concrete is critical for ensuring structural integrity and durability of concrete structures, especially in environments prone to severe weather conditions. Accurate air content analysis optimizes concrete's resistance to freeze-thaw cycles and enhances its workability and strength. Several methods are standardized under ASTM guidelines to measure the air content in fresh concrete, each suitable for different concrete types and conditions.
The pressure method,...
The pressure method,...
183
Moisture Content and Bulking of Aggregate
178
The moisture content of aggregates is a crucial factor in construction, particularly in concrete mixing, as it influences the total water required in the mix. Moisture content represents the water coated on the exterior surface of the aggregate existing in a saturated and surface-dry condition. The total water content of a moist aggregate is the sum of its moisture content and water absorption.
When aggregates are exposed to rain or sit in stockpiles, they absorb moisture, which must be...
When aggregates are exposed to rain or sit in stockpiles, they absorb moisture, which must be...
178
Bending of Members Made of Several Materials
223
In analyzing a structural member composed of two different materials with identical cross-sectional areas, it is crucial to understand how their distinct elastic properties affect the member's response under load. The analysis involves assessing stress and strain distributions using the transformed section concept, which accounts for variations in material properties.
Hooke's Law determines stress in each material, stating that stress is proportional to strain but varies due to each...
Hooke's Law determines stress in each material, stating that stress is proportional to strain but varies due to each...
223
Compacting Factor test
187
The compacting factor test is a method used to assess the workability of concrete. It is especially suitable for concrete mixes containing aggregates up to one and a half inches in size. This test involves specialized equipment consisting of two truncated cone-shaped hoppers and a cylinder, all with polished interior surfaces to minimize friction.
The procedure begins by placing concrete into the upper hopper without any compaction. Once filled, the bottom door of this hopper is opened,...
The procedure begins by placing concrete into the upper hopper without any compaction. Once filled, the bottom door of this hopper is opened,...
187