基于多尺度移动波反应功率和随机森林的T连接输电线路故障识别的新方法
Yawen Zhong1, Jie Yang2, Sheng Wang3
1School of Engineering, Southwest Petroleum University, Nanchong, Sichuan, China.
PloS one
|August 18, 2023
概括
这项研究引入了一种用于T连接输电线路故障诊断的新方法. 它使用多级移动波反应功率和随机森林准确识别特定的故障分支,提高可靠性.
科学领域:
- 电气工程 电气工程
- 电力系统 电力系统
- 错误诊断 错误诊断 错误诊断 是一个
背景情况:
- 对T连接输电线路的传统故障诊断方法可以区分内部和外部故障,但无法确定特定的分支.
- 这种局限性需要更精确的方法来准确地定位复杂的输电线路配置中的故障.
研究的目的:
- 开发和验证一种新的方法,用于识别T连接输电线路中的特定故障分支.
- 提高这些系统中故障诊断的准确性和可靠性.
主要方法:
- 利用S变换来分析多尺度移动波的反应功率.
- 每个保护单元的多个频率的移动波反应功率的计算平均和总比.
- 开发了一种随机森林模型,在一个故障特征样本上训练,用于分支识别.
主要成果:
- 拟议的算法准确且快速地识别T连接输电线路内的特定故障分支.
- 在各种工作条件中证明有效,包括CT和,噪音和数据丢失的场景.
- 成功区分了保护区内外的断层.
结论:
- 拟议的方法显著提高了T连接输电线路故障诊断的准确性和可靠性.
- 它提供了一个强大的解决方案,用于识别特定的故障分支,即使在具有挑战性的电力系统条件下.
更多相关视频
相关概念视频
Power System Three-Phase Short Circuits
109
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
109
The Power Flow Problem and Solution
258
Power flow problem analysis is fundamental for determining real and reactive power flows in network components, such as transmission lines, transformers, and loads. The power system's single-line diagram provides data on the bus, transmission line, and transformer. Each bus k in the system is characterized by four key variables: voltage magnitude Vk, phase angle δk, real power Pk, and reactive power Qk. Two of these four variables are inputs, while the...
258
Traveling Waves: Lossless Lines
157
The provided content explores the behavior of traveling waves on single-phase lossless transmission lines. It begins with a single-phase two-wire lossless transmission line of length Δx, characterized by a loop inductance LH/m and a line-to-line capacitance C F/m. These parameters result in a series inductance LΔx and a shunt capacitance CΔx.
157
Fault Types
106
When analyzing a single line-to-ground fault from phase A to ground at a three-phase bus, it is important to consider the fault impedance. This impedance is zero for a bolted fault, equal to the arc impedance for an arcing fault, and represents the total fault impedance for a transmission-line insulator flashover. To derive sequence and phase currents, fault conditions are translated from the phase domain to the sequence domain.
For line-to-line faults occurring between phases B and C, the...
For line-to-line faults occurring between phases B and C, the...
106
Maximum Power Flow and Line Loadability
138
The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
138
Transmission-Line Differential Equations
340
Transmission lines are essential components of electrical power systems. They are characterized by the distributed nature of resistance (R), inductance (L), and capacitance (C) per unit length. To analyze these lines, differential equations are employed to model the variations in voltage and current along the line.
Line Section Model
A circuit representing a line section of length Δx helps in understanding the transmission line parameters. The voltage V(x) and current i(x) are measured...
Line Section Model
A circuit representing a line section of length Δx helps in understanding the transmission line parameters. The voltage V(x) and current i(x) are measured...
340