了解纵横断面分辨率对声学调查的影响
Guillermo Boyra1, Iosu Paradinas2,3, Iñaki Rico2
1AZTI, Herrera Kaia, Portualdea z/g, 20110, Pasaia, Gipuzkoa, Spain. gboyra@azti.es.
Scientific reports
|August 22, 2023
概括
降低声学调查分辨率增加了鱼类丰富性估计的不确定性. 降低的ping速率放大了偏差,特别是在异质区域,可能导致低估.
科学领域:
- 海洋声学 海洋声学
- 渔业科学 渔业科学
- 生态采样 生态采样
背景情况:
- 声学调查对于估计鱼类丰富度至关重要.
- 采样分辨率,通过声波探测器 ping 间隔和船舶速度来确定,影响数据质量.
- 减少分辨率可以在丰富度估计中引入不确定性和偏差.
研究的目的:
- 调查减少沿横截面采样分辨率对声丰度估计的影响.
- 要确定分辨率下降是否会影响平均反向散射的声能,并引入偏差.
- 探索截面异质性和空间自相对应对分辨率相关错误的影响.
主要方法:
- 一个现有的声学调查数据集被回声集成.
- 应用了重新抽样方案来模拟不同的ping分辨率.
- 平均反向散射的声能被比较在不同分辨率的每个穿越.
- 截面特征 (异质性,空间自相关性) 分析了与丰度错误的关系.
主要成果:
- 随着采样分辨率的下降,丰度估计的不确定性增加.
- 较高的截面异质性和较低的空间自相关性加剧了精度不准确,分辨率降低.
- 虽然平均偏差为零,但偏差分布变得不对称,增加了低估概率和幅度.
结论:
- 声学调查分辨率的下降显著增加了不确定性和潜在的低估鱼类丰富性.
- 交易特征极大地影响抽样解决方案对数据可靠性的影响.
- 优化ping速率和考虑调查区域属性对于准确的声丰度估计至关重要.
相关概念视频
Aliasing
161
Accurate signal sampling and reconstruction are crucial in various signal-processing applications. A time-domain signal's spectrum can be revealed using its Fourier transform. When this signal is sampled at a specific frequency, it results in multiple scaled replicas of the original spectrum in the frequency domain. The spacing of these replicas is determined by the sampling frequency.
If the sampling frequency is below the Nyquist rate, these replicas overlap, preventing the original...
If the sampling frequency is below the Nyquist rate, these replicas overlap, preventing the original...
161
Common Leveling Mistakes and Errors
96
A survey team is tasked with determining the elevation difference between points Point A and Point B, separated by uneven terrain. They use a leveling instrument and a leveling rod.Common MistakesMisreading the Rod: During a backsight reading at Point A, the instrumentman observes the rod partially obscured by tall grass. Instead of reading 1.135 m, they mistakenly record 1.735 m due to the misalignment of the crosshair with the wrong graduation. This error adds 0.600 m to all subsequent...
96
Echo
534
The human ear cannot distinguish between two sources of sound if they happen to reach within a specific time interval, typically 0.1 seconds apart. More than this, and they are perceived as separate sources.
Imagine the sound is reflected back to the ears. Assuming that the source is very close to the human, the difference between hearing the two sounds—the emitted sound and the reflected sound—may be more than the minimum time for perceiving distinct sounds. If this is the case,...
Imagine the sound is reflected back to the ears. Assuming that the source is very close to the human, the difference between hearing the two sounds—the emitted sound and the reflected sound—may be more than the minimum time for perceiving distinct sounds. If this is the case,...
534
Types of Global Positioning System Surveys
77
GPS surveying methods vary in application, accuracy, and data collection techniques, catering to diverse surveying and mapping needs. Static GPS, kinematic GPS, and real-time kinematic (RTK) surveying are widely used. Each technique offers distinct advantages.Static GPS involves placing one receiver at a known reference point and another at the target point. It collects exact positional data by observing multiple satellite ranges over an extended period, achieving centimeter-level accuracy for...
77
Adjusting a Traverse
80
In the site survey of a four-sided traverse, internal angles are essential to ensure geometric accuracy. The survey revealed that the sum of the measured internal angles was 359 degrees and 48 minutes, which is 12 minutes less than the expected 360 degrees. This discrepancy signals an error likely arising from measurement inaccuracies during the fieldwork.To rectify this error, the adjustment process involved distributing the 12-minute shortfall equally across the four internal angles. By...
80
Mass Analyzers: Overview
724
The mass analyzer is a crucial component of the mass spectrometer. In the ionization chamber, the vaporized sample is bombarded with a high-energy electron beam to generate a radical cation and further fragment into neutral molecules, radicals, and cations. A series of negatively charged accelerator plates accelerate the cations into the mass analyzer. The mass analyzer separates ions according to their mass-to-charge (m/z) ratios and then directs them to the detector. The common types of mass...
724


