一个8-18 GHz 90°开关的T型相位变速器
Jialong Zeng1,2, Yuxin Ren1,2, Cheng Tan1
1Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China.
Micromachines
|August 26, 2023
概括
本研究引入了一种增强的8-18 GHz T型相位变换器 (TPS),具有更好的相位变换能力和宽带平面相对相位变换. 这种新的设计为超宽带无线通信和雷达系统提供了出色的性能.
科学领域:
- 电气工程 电气工程
- 微波工程 微波工程
- 半导体设备 半导体设备
背景情况:
- 传统的T型相位转换器 (TPS) 在相位转换能力和宽带性能方面经常面临限制.
- 在广泛的频率范围内实现平面相对相位移对于先进的无线和雷达应用至关重要.
研究的目的:
- 提出和验证一种具有增强性能的新型8-18 GHz 90°开关T型相位变换器 (TPS).
- 提高相位转移能力,在宽带上实现相对平坦的相位转移.
主要方法:
- 设计和制造一种新型的TPS,包括一个补偿电容和一个过补偿网络.
- 使用0.15μm GaAs pHEMT技术用于设备制造.
- 在8-18 GHz频段的相位移,相位误差和插入损失的实验性表征.
主要成果:
- 拟议的TPS实现了从8-18 GHz的均相位移,测量相位误差小于±1.5°.
- 该设备的插入损失在1.3-2.6dB之间.
- 制造的芯片尺寸是紧的,尺寸为0.53 × 0.86 mm2.
结论:
- 新的TPS设计显著提高了相位转移能力,并在宽带上提供了平坦的相对相位转移.
- 卓越的性能,包括低相误差和插入损失,使该设备适合超宽带无线通信和雷达系统.
- 紧的尺寸进一步提高了其在空间有限的系统中的适用性.
相关概念视频
Phase-lead and Phase-lag Controllers
194
Understanding the working function of different types of controllers can be illustrated with practical analogies, such as adjusting a stereo's volume equalizer. Cranking up the bass involves a phase-lead controller, which functions as a high-pass filter, while increasing the treble uses a phase-lag controller, which acts as a low-pass filter. PD controllers, similar to high-pass filters, enhance the system's response to high-frequency components. PI controllers, akin to low-pass...
194
Time and frequency -Domain Interpretation of Phase-lead Control
102
Phase-lead controllers are commonly used in various control systems to enhance response speed and stability. Adjusting the brightness on a television screen offers a practical example of phase-lead control. When contrast is enhanced, a phase-lead controller is employed. Mathematically, phase-lead control is identified when the first parameter is smaller than the second.
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
102
Time and frequency -Domain Interpretation of Phase-lag Control
115
Phase-lag controllers are widely used in control systems to improve stability and reduce steady-state errors. A dimmer switch controlling the brightness of a light bulb serves as a practical example of phase-lag control, gradually adjusting the bulb's brightness. Mathematically, phase-lag control or low-pass filtering is represented when the factor 'a' is less than 1.
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any...
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any...
115
Three-Phase Circuits
435
AC power distribution systems have three categories: single-phase, two-phase, and three-phase systems. The single-phase circuit, common in residential settings, typically employs a two-wire system connecting a single AC source to various loads. These circuits support standard household appliances operating at 120 volts (V) and 240 V, such as lamps, televisions, and microwaves. The first generators, Niagara Falls hydro plant installed in 1895, were two-phase and designed by Nikola Tesla. The...
435
Half wave rectifier
1.2K
A half-wave rectifier is a fundamental circuit in electronics, designed to convert alternating current (AC) voltage into a unidirectional voltage. It utilizes the simplest form of diode rectification, where the circuit comprises a single diode in series with a load resistor and an AC power source.
1.2K
Series Impedances: Three-Phase Line
130
Calculating series impedances for a three-phase overhead line involves evaluating resistances and inductive reactances in a network with three-phase and multiple neutral conductors grounded at regular intervals.
Using Kirchhoff's laws, an integro-differential equation for the network is derived. This equation accounts for unbalanced phase currents, which may induce return currents through neutral wires and the earth, seeking the least impedance path. Earth return conductors can replace the...
Using Kirchhoff's laws, an integro-differential equation for the network is derived. This equation accounts for unbalanced phase currents, which may induce return currents through neutral wires and the earth, seeking the least impedance path. Earth return conductors can replace the...
130


